 浏览型号DCM4623TD2K26E0M70的Datasheet PDF文件第12页浏览型号DCM4623TD2K26E0M70的Datasheet PDF文件第13页浏览型号DCM4623TD2K26E0M70的Datasheet PDF文件第14页浏览型号DCM4623TD2K26E0M70的Datasheet PDF文件第15页浏览型号DCM4623TD2K26E0M70的Datasheet PDF文件第17页浏览型号DCM4623TD2K26E0M70的Datasheet PDF文件第18页浏览型号DCM4623TD2K26E0M70的Datasheet PDF文件第19页浏览型号DCM4623TD2K26E0M70的Datasheet PDF文件第20页  
DCM4623xD2K26E0y7z  
The DCM will latch trim behavior at application of VIN (once VIN  
exceeds VIN-UVLO+), and persist in that same behavior until loss of  
input voltage.  
n At application of VIN, if TR is sampled at above VTRIM-DIS, the  
module will latch in a non-trim mode, and will ignore the TR  
input for as long as VIN is present.  
Pin Functions  
+IN, -IN  
Input power pins. -IN is the reference for all control pins, and  
therefore a Kelvin connection for the control signals is  
recommended as close as possible to the pin on the package, to  
reduce effects of voltage drop due to -IN currents.  
n At application of VIN, if TR is sampled at below VTRIM-EN, the TR  
will serve as an input to control the real time output voltage,  
relative to full load, 25°C. It will persist in this behavior until VIN is  
no longer present.  
+OUT, -OUT  
Output power pins.  
If trim is active when the DCM is operating, the TR pin provides  
dynamic trim control at a typical 30 Hz of -3dB bandwidth over the  
output voltage. TR also decreases the current limit threshold when  
EN (Enable)  
This pin enables and disables the DCM converter; when held low the  
unit will be disabled. It is referenced to the -IN pin of the converter.  
The EN pin has an internal pull-up to VCC through a  
10 kΩ resistor.  
n Output enable: When EN is allowed to pull up above the enable  
threshold, the module will be enabled. If leaving EN floating, it is  
pulled up to VCC and the module will be enabled.  
trimming above VOUT-NOM  
.
FT (Fault)  
The FT pin provides a Fault signal.  
Anytime the module is enabled and has not recognized a fault, the  
FT pin is inactive. FT has an internal 499 kΩ pull-up to Vcc, therefore  
a shunt resistor, RSHUNT, of approximately 50 kΩ can be used to  
ensure the LED is completly off when there is no fault, per the  
diagram below.  
n Output disable: EN may be pulled down externally in order  
to disable the module.  
n EN is an input only, it does not pull low in the event of a fault.  
Whenever the powertrain stops (due to a fault protection or  
disabling the module by pulling EN low), the FT pin becomes active  
and provides current to drive an external circuit.  
TR (Trim)  
The TR pin is used to select the trim mode and to trim the output  
voltage of the DCM converter. The TR pin has an internal pull-up to  
When active, FT pin drives to VCC, with up to 4 mA of external  
loading. Module may be damaged from an over-current FT drive,  
thus a resistor in series for current limiting is recommended.  
VCC through a 10.0 kΩ resistor.  
The FT pin becomes active momentarily when the module starts up.  
Typical External Circuits for Signal Pins (TR, EN, FT)  
Vcc  
Vcc  
Vcc  
Fault  
Monitoring  
499k  
10k  
10k  
Output Voltage  
Reference,  
Soft Start and  
Fault Monitoring  
Current Limit  
Reference  
and Soft Start Control  
FT  
TR  
EN  
SW  
RSERIES  
RTRIM  
RSHUNT  
Kelvin -IN connection  
DCMDC-DC Converter  
Rev 1.0  
Page 16 of 23  