 浏览型号DCM4623TD2H31E0M00的Datasheet PDF文件第16页浏览型号DCM4623TD2H31E0M00的Datasheet PDF文件第17页浏览型号DCM4623TD2H31E0M00的Datasheet PDF文件第18页浏览型号DCM4623TD2H31E0M00的Datasheet PDF文件第19页浏览型号DCM4623TD2H31E0M00的Datasheet PDF文件第21页浏览型号DCM4623TD2H31E0M00的Datasheet PDF文件第22页浏览型号DCM4623TD2H31E0M00的Datasheet PDF文件第23页浏览型号DCM4623TD2H31E0M00的Datasheet PDF文件第24页  
DCM4623xD2H31E0yzz  
temperature fault is registered, the powertrain immediately stops  
switching, the output voltage of the converter falls, and the converter  
remains disabled for at least time tFAULT. Then, the converter waits for  
the internal temperature to return to below TINT-OTP before  
The ChiP package provides a high degree of flexibility in that it  
presents three pathways to remove heat from internal power  
dissipating components. Heat may be removed from the top surface,  
the bottom surface and the leads. The extent to which these three  
surfaces are cooled is a key component for determining the  
maximum power that is available from a ChiP, as can be seen from  
Figure 20.  
recovering. Provided the converter is still enabled, the DCM will  
restart after tINIT and tON  
.
Output Overvoltage Fault Protection (OVP)  
Since the ChiP has a maximum internal temperature rating, it is  
necessary to estimate this internal temperature based on a real  
thermal solution. Given that there are three pathways to remove heat  
from the ChiP, it is helpful to simplify the thermal solution into a  
roughly equivalent circuit where power dissipation is modeled as a  
current source, isothermal surface temperatures are represented as  
voltage sources and the thermal resistances are represented as  
resistors. Figure 20 shows the "thermal circuit" for a 4623 ChiP DCM,  
in an application where both case top and case bottom, and leads are  
The converter monitors the output voltage during each switching  
cycle by a corresponding voltage reflected to the primary side control  
circuitry. If the primary sensed output voltage exceeds VOUT-OVP, the  
OVP fault protection is triggered. The control logic disables the  
powertrain, and the output voltage of the converter falls.  
This type of fault is latched, and the converter will not start again  
until the latch is cleared. Clearing the fault latch is achieved by either  
disabling the converter via the EN pin, or else by removing the input  
cooled. In this case, the DCM power dissipation is PD  
TOTAL and the  
power such that the input voltage falls below VIN-INIT  
.
three surface temperatures are represented as TCASE_TOP, TCASE_BOTTOM  
and TLEADS. This thermal system can now be very easily analyzed  
with simple resistors, voltage sources, and a current source.  
,
External Output Capacitance  
The DCM converter internal compensation requires a minimum  
external output capacitor. An external capacitor in the range of 200  
to 2000 µF with ESR of 10 mΩ is required, per DCM for control loop  
compensation purposes.  
This analysis provides an estimate of heat flow through the various  
pathways as well as internal temperature.  
However some DCM models require an increase to the minimum  
external output capacitor value in certain loading and trim  
condition. In applications where the load can go below 10% of rated  
load but the output trim is held constant, the range of output  
capacitor required is given by COUT-EXT-TRANS in the Electrical  
Specifications table. If the load can go below 10% of rated load and  
the DCM output trim is also dynamically varied, the range of output  
capacitor required is given by COUT-EXT-TRANS-TRIM in the Electrical  
Specifications table.  
Thermal Resistance Top  
INT-TOP°C / W  
MAX INTERNAL TEMP  
θ
Thermal Resistance Bottom  
INT-BOTTOM°C / W  
Thermal Resistance Leads  
θ
θI­NT-LEADS°C / W  
+
+
+
T
CASE_BOTTOM(°C)  
TLEADS(°C)  
TCASE_TOP(°C)  
Power Dissipation (W)  
Light Load Boosting  
Under light load conditions, the DCM converter may operate in light  
load boosting depending on the line voltage. Light load boosting  
occurs whenever the internal power consumption of the converter  
combined with the external output load is less than the minimum  
power transfer per switching cycle. In order to maintain regulation,  
the error amplifier will switch the powertrain off and on repeatedly,  
to effectively lower the average switching frequency, and permit  
operation with no external load. During the time when the power  
train is off, the module internal consumption is significantly  
reduced, and so there is a notable reduction in no-load input power  
in light load boosting. When the load is less than 10% of rated Iout,  
the output voltage may rise by a maximum of 2.95 V, above the  
output voltage calculated from trim, temperature, and load line  
conditions.  
Figure 20 Double side cooling and leads thermal model  
Alternatively, equations can be written around this circuit and  
analyzed algebraically:  
TINT – PD1 θINT-TOP = TCASE_TOP  
TINT – PD2 θINT-BOTTOM = TCASE_BOTTOM  
TINT – PD3 θINT-LEADS = TLEADS  
PDTOTAL = PD1+ PD2+ PD3  
Where TINT represents the internal temperature and PD1, PD2, and  
PD3 represent the heat flow through the top side, bottom side, and  
leads respectively.  
Thermal Design  
Based on the safe thermal operating area shown in page 5, the full  
rated power of the DCM4623xD2H31E0yzz can be processed  
provided that the top, bottom, and leads are all held below 90°C.  
These curves highlight the benefits of dual sided thermal  
management, but also demonstrate the flexibility of the Vicor ChiP  
platform for customers who are limited to cooling only the top or the  
bottom surface.  
Thermal Resistance Top  
INT-TOP°C / W  
MAX INTERNAL TEMP  
θ
Thermal Resistance Bottom  
INT-BOTTOM°C / W  
Thermal Resistance Leads  
θ
θINT-LEADS°C / W  
+
+
T
CASE_BOTTOM(°C)  
TLEADS(°C)  
TCASE_TOP(°C)  
Power Dissipation (W)  
The OTP sensor is located on the top side of the internal PCB  
structure. Therefore in order to ensure effective over-temperature  
fault protection, the case bottom temperature must be constrained  
by the thermal solution such that it does not exceed the temperature  
of the case top.  
Figure 21 One side cooling and leads thermal model  