 浏览型号DCM4623TC8G16F0T00的Datasheet PDF文件第9页浏览型号DCM4623TC8G16F0T00的Datasheet PDF文件第10页浏览型号DCM4623TC8G16F0T00的Datasheet PDF文件第11页浏览型号DCM4623TC8G16F0T00的Datasheet PDF文件第12页浏览型号DCM4623TC8G16F0T00的Datasheet PDF文件第13页浏览型号DCM4623TC8G16F0T00的Datasheet PDF文件第14页浏览型号DCM4623TC8G16F0T00的Datasheet PDF文件第15页浏览型号DCM4623TC8G16F0T00的Datasheet PDF文件第16页  
nThe –IN lugs must be connected together if the paralleling connector is used, or if the EN, TR,  
or FT pins are interconnected in any fashion. However if all control signals of all DCMs are fully  
isolated from one another, then both the +IN and –IN lugs can remain independent across the  
evaluation boards, and the DCMs can be operated with fully independent input supplies.  
nStandoffs must be sufficient in length to avoid contact between boards, and to permit airflow to  
all DCMs in the system.  
nIf coordinated enable control, trimming or fault monitoring is desired, then the paralleling connectors  
J09 & J10 can be used to easily interconnect the PRI_FT, PRI_EN, PRI_TR_ and PRI_FT  
nodes across boards.  
The paralleling connectors at J02 & J03 can be used for coordinated enable and trim control and fault  
monitoring. The enable, trim and fault monitor features of the top most board should be used for  
convenience, while the remaining boards should have their jumper blocks depopulated and enable  
switches set to enable.  
The paralleling wire-to-board connectors (at J02 and J03) are provided to daisy chain control signals and  
PRI_SG, with a simple strip and insert option. They will accept 18 – 24 AWG solid wires.  
Figure 7  
DCM evaluation boards stacked  
to form a high power parallel  
array, using common -IN and  
the paralleling connectors.  
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is  
assumed by Vicor for its use. Vicor components are not designed to be used in applications, such  
as life support systems, wherein a failure or malfunction could result in injury or death. All sales are  
subject to Vicor’s Terms and Conditions of Sale, which are available upon request.  
Specifications are subject to change without notice.  
Rev 1.6  
04/17  
vicorpower.com  
Applications Engineering: 800 927.9474  
Page 17  