BCM4414xH0E5035yzz
Application Characteristics (Cont.)
Temperature controlled via pin-side cold plate, unless otherwise noted. All data presented in this section are collected from units processing power in the
forward direction (high-voltage side to low-voltage side). See associated figures for general trend data.
99
98
97
96
95
94
93
92
91
90
89
88
87
50
45
40
35
30
25
20
15
10
5
0
0
5
10
15
20
25
30
800V
35
0
5
10
LO-Side Output Current (A)
500V 650V
15
20
25
30
800V
35
LO-Side Output Current (A)
VHI_DC
:
VHI_DC
:
500V
650V
Figure 10 — Efficiency at TCASE = 70°C
Figure 11 — Power dissipation at TCASE = 70°C
25
20
280
240
200
160
120
80
15
10
5
40
0
–55
0
–30
–5
20
45
70
0
5
10
LO-Side Output Current (A)
VHI_DC 650V
15
20
25
30
35
Case Temperature (ºC)
ILO_DC
:
35A
:
Figure 12 — RLO vs. temperature; nominal VHI_DC, ILO_DC = 35A
Figure 13 — VLO_OUT_PP vs. ILO_DC ; no external CLO_OUT_EXT
.
Board-mounted module, scope setting:
20MHz analog BW
BCM® in a VIA™ Package
Page 15 of 43
Rev 1.0