BCM4414xD1E2663yzz
Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
–40°C ≤ TCASE ≤100°C (T-Grade); all other specifications are at TCASE = 25ºC unless otherwise noted.
Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Powertrain Supervisory Limits Specification – Forward Direction Operation (High Voltage Side to Low Voltage Side)
• These supervisory limits are set in the internal controller and can be reconfigured or disabled through PMBus™.
• When disabled, the powertrain protections presented in the previous table will intervene during fault events.
HI Side Overvoltage
Lockout Threshold
VHI_OVLO+
VHI_OVLO–
VHI_OVLO_HYST
tHI_OVLO
420
410
435
425
10
450
440
V
V
HI Side Overvoltage
Recovery Threshold
HI Side Overvoltage
Lockout Hysteresis
V
HI Side Overvoltage
Lockout Response Time
100
225
240
15
µs
V
HI Side Undervoltage
Lockout Threshold
VHI_UVLO–
200
220
250
259
HI Side Undervoltage
Recovery Threshold
VHI_UVLO+
VHI_UVLO_HYST
tHI_UVLO
V
HI Side Undervoltage
Lockout Hysteresis
V
HI Side Undervoltage
Lockout Response Time
100
µs
From VHI_DC = VHI_UVLO+ to powertrain active,
HI Side Undervoltage Start-Up Delay tHI_UVLO+_DELAY (i.e., one time start-up delay from application of VHI_DC
to VLO_DC
20
ms
)
LO Side Overcurrent Trip Threshold
ILO_OUT_OCP
tLO_OUT_OCP
tOTP+
83
88
3
93
A
LO Side Overcurrent
Response Time Constant
Effective internal RC filter
Internal
ms
°C
°C
Overtemperature
Shutdown Threshold
125
Overtemperature
Recovery Threshold
tOTP–
Internal
105
110
115
C-Grade
T-Grade
–25
–45
Undertemperature Shutdown
Threshold (Internal)
tUTP
°C
s
Start up into a persistent fault condition. Non-latching
fault detection given VHI_DC > VHI_UVLO+
Undertemperature Restart Time
tUTP_RESTART
3
BCM® in a VIA Package
Page 8 of 43
Rev 1.1
01/2018