欢迎访问ic37.com |
会员登录 免费注册
发布采购

BCM4414VD1E13A2C02 参数 Datasheet PDF下载

BCM4414VD1E13A2C02图片预览
型号: BCM4414VD1E13A2C02
PDF下载: 下载PDF文件 查看货源
内容描述: [DC DC CONVERTER 12V 1500W]
分类和应用:
文件页数/大小: 43 页 / 4056 K
品牌: VICOR [ VICOR CORPORATION ]
 浏览型号BCM4414VD1E13A2C02的Datasheet PDF文件第33页浏览型号BCM4414VD1E13A2C02的Datasheet PDF文件第34页浏览型号BCM4414VD1E13A2C02的Datasheet PDF文件第35页浏览型号BCM4414VD1E13A2C02的Datasheet PDF文件第36页浏览型号BCM4414VD1E13A2C02的Datasheet PDF文件第38页浏览型号BCM4414VD1E13A2C02的Datasheet PDF文件第39页浏览型号BCM4414VD1E13A2C02的Datasheet PDF文件第40页浏览型号BCM4414VD1E13A2C02的Datasheet PDF文件第41页  
BCM4414xD1E13A2yzz  
3. The unsupported PMBus command code response as described  
in the Fault Management and Reporting:  
The BCM Controller Implementation vs.  
PMBus® Specification Rev 1.2  
ꢀnDeviations from the PMBus specification:  
a. PMBus section 10.2.5.3, exceptions  
The BCM controller is an I2C compliant, SMBus™ compatible device  
and PMBus command compliant device. This section denotes some  
deviation, perceived as differences from the PMBus Part I and Part II  
specification Rev 1.2.  
• The busy bit of the STATUS_BYTE as implemented can  
be cleared (80h). In order to maintain compatibility with  
the specification, (40h) can also be used.  
1. The PMBus interface meets all Part I and II PMBus specification  
requirements with the following differences to the  
transport requirement.  
nManufacturer Implementation of the PMBus Spec:  
a. PMBus section 10.5, setting the response to a detected  
fault condition  
Unmet DC parameter Implementation vs SMBus™ spec  
• All powertrain responses are pre-set and cannot be  
changed.  
PMBus  
Interface  
SMBus™  
Rev 2.0  
Symbol  
Parameter  
Units  
Min Max Min Max  
b. PMBus section 10.6, reporting faults and warnings  
[a]  
to the Host  
VIL  
Input Low Voltage  
Input High Voltage  
Input Leakage per Pin  
-
0.99  
-
-
0.8  
V
V
[a]  
• SMBALERT# signal and Direct PMBus Device to Host  
Communication are not supported. However, the  
PMBus interface will set the corresponding fault status  
bits and will wait for the host to poll.  
VIH  
2.31  
10  
2.1 VVDD_IN  
[b]  
ILEAK_PIN  
22  
-
5
µA  
[a]  
V
= 3.3V  
VDD_IN  
[b]  
V
= 5V  
BUS  
c. PMBus section 10.7, clearing a shutdown due to a fault  
2.The BCM controller accepts 38 PMBus command codes.  
Implemented commands execute functions as described in the  
PMBus specification.  
• There is no RESET pin or EN pin in the BCM. Cycling  
power to the BCM will not clear a BCM Shutdown. The  
BCM will clear itself once the fault condition is removed.  
nDeviations from the PMBus specification:  
a. Section 15, fault related commands  
d. PMBus Section 10.8.1, corrupted data transmission faults:  
• Packet error checking is not supported.  
• The Limits and Warnings unit is implemented as a  
percentage (%) range from decimal (0-100) of the  
factory set limits.  
Data Transmission Faults Implementation  
This section describes data transmission faults as implemented in the BCM controller.  
Response to Host  
STATUS_BYTE  
STATUS_CML  
Section  
Description  
Notes  
Unsupported  
NAK  
FFh  
CML  
Other Fault  
Data  
10.8.1  
10.8.2  
10.8.3  
Corrupted data  
No response; PEC not supported  
Sending too few bits  
Reading too few bits  
X
X
X
X
Host sends or reads too  
few bytes  
10.8.4  
X
X
Host sends too many  
bytes  
10.8.5  
10.8.6  
X
X
X
X
X
Reading too many bytes  
X
X
X
Device will ACK own address  
BUSY bit in STATUS_BYTE even if  
STATUS_WORD is set  
10.8.7  
Device busy  
BCM® in a VIA™ Package  
Page 37 of 43  
Rev 1.7  
08/2020  
 复制成功!