BCM4414xD1E13A2yzz
READ_VIN Command (88h)
READ_POUT Command (96h)
If PAGE data byte is equal to (01h), command will return the BCM’s
HI side voltage in the following format:
If PAGE data byte is equal to (01h), command will return the BCM’s
LO side power in the following format:
VHI_ACTUAL = VHI_REPORTED • 10-1(V)
PLO_ACTUAL = PLO_REPORTED (W)
If PAGE data byte is equal to (00h), command will also return the
BCM’s LO side power.
READ_IIN Command (89h)
If PAGE data byte is equal to (01h), command will return the BCM’s
HI side current in the following format:
MFR_VIN_MIN Command (A0h),
MFR_VIN_MAX Command (A1h),
MFR_VOUT_MIN Command (A4h),
MFR_VOUT_MAX Command (A5h),
MFR_IOUT_MAX Command (A6h),
MFR_POUT_MAX Command (A7h)
IHI_ACTUAL = IHI_REPORTED • 10-3(A)
If PAGE data byte is equal (00h), command will also return the
BCM’s HI side current.
READ_VOUT Command (8Bh)
These values are set by the factory and indicate the device
HI side/LO side voltage and LO side current range and LO side
power capacity.
If PAGE data byte is equal to (01h), command will return the BCM’s
LO side voltage in the following format:
If the PAGE data byte is equal to (00h - 01h), commands report the
rated BCM HI side voltage minimum and maximum in Volts, LO side
voltage minimum and maximum in Volts, LO side current maximum
in Amperes and LO side power maximum in Watts.
VLO_ACTUAL = VLO_REPORTED • 10-1(V)
READ_IOUT Command (8Ch)
If PAGE data byte is equal to (01h), command will return the BCM’s
LO side current in the following format:
ILO_ACTUAL = ILO_REPORTED • 10-2(A)
If PAGE data byte is equal (00h), command will also return the
BCM’s LO side current.
READ_TEMPERATURE_1 Command (8Dh)
If PAGE data byte is equal to (01h), command will return the BCM’s
temperature in the following format:
TACTUAL = TREPORTED (°C)
If PAGE data byte is equal (00h), command will also return the
BCM’s temprature.
BCM® in a VIA™ Package
Page 35 of 43
Rev 1.7
08/2020