 浏览型号BCM384Y120X1K5AC1的Datasheet PDF文件第4页浏览型号BCM384Y120X1K5AC1的Datasheet PDF文件第5页浏览型号BCM384Y120X1K5AC1的Datasheet PDF文件第6页浏览型号BCM384Y120X1K5AC1的Datasheet PDF文件第7页浏览型号BCM384Y120X1K5AC1的Datasheet PDF文件第9页浏览型号BCM384Y120X1K5AC1的Datasheet PDF文件第10页浏览型号BCM384Y120X1K5AC1的Datasheet PDF文件第11页浏览型号BCM384Y120X1K5AC1的Datasheet PDF文件第12页  
BCM384y120x1K5AC1  
Reported Characteristics  
Specifications apply over all line, load conditions, unless otherwise noted; Boldface specifications apply over the temperature range of -40°C TINTERNAL  
125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.  
Monitored Telemetry  
• The BCM communication version is not intended to be used without a Digital Supervisor.  
DIGITAL SUPERVISOR  
PMBusTM READ COMMAND  
UPDATE  
RATE  
ACCURACY  
(RATED RANGE)  
FUNCTIONAL  
REPORTING RANGE  
ATTRIBUTE  
REPORTED UNITS  
Input voltage  
(88h) READ_VIN  
(89h) READ_IIN  
5% ( LL - HL )  
5% ( 10 - 133% of FL)  
5% ( LL - HL )  
130 V to 450 V  
- 0.85 A to 5.9 A  
4.25 V to 14 V  
100 µs  
100 µs  
100 µs  
100 µs  
100 ms  
100 ms  
VACTUAL = VREPORTED x 10-1  
IACTUAL = IREPORTED x 10-3  
VACTUAL = VREPORTED x 10-1  
IACTUAL = IREPORTED x 10-2  
RACTUAL = RREPORTED x 10-5  
TACTUAL = TREPORTED  
Input current  
Output voltage[1]  
Output current  
Output resistance  
Temperature[2]  
(8Bh) READ_VOUT  
(8Ch) READ_IOUT  
5% ( 10 - 133% of FL )  
5% ( 50 - 100% of FL)  
7°C ( Full Range)  
- 27 A to 190 A  
1.0 mΩ to 3.0 mΩ  
- 55ºC to 130ºC  
(D4h) READ_ROUT  
(8Dh) READ_TEMPERATURE_1  
[1] Default READ Output Voltage returned when unit is disabled = -300 V.  
[2] Default READ Temperature returned when unit is disabled = -273°C.  
Variable Parameter  
• Factory setting of all below Thresholds and Warning limits are 100% of listed protection values.  
• Variables can be written only when module is disabled either EN pulled low or VIN < VIN_UVLO-  
.
• Module must remain in a disabled mode for 3 ms after any changes to the below variables allowing ample time to commit changes to EEPROM.  
FUNCTIONAL  
REPORTING  
RANGE  
DIGITAL SUPERVISOR  
PMBusTM COMMAND [3]  
DEFAULT  
VALUE  
ACCURACY  
(RATED RANGE)  
ATTRIBUTE  
CONDITIONS / NOTES  
Input / Output Overvoltage  
Protection Limit  
VIN_OVLO- is automatically 3%  
lower than this set point  
(55h) VIN_OV_FAULT_LIMIT  
(57h) VIN_OV_WARN_LIMIT  
(D7h) DISABLE_FAULTS  
(5Bh) IIN_OC_FAULT_LIMIT  
(5Dh) IIN_OC_WARN_LIMIT  
(4Fh) OT_FAULT_LIMIT  
5% ( LL - HL )  
5% ( LL - HL )  
130 V to 435 V  
130 V to 435 V  
130 V or 260 V  
0 to 5.25 A  
100%  
100%  
100%  
100%  
100%  
100%  
100%  
0 ms  
Input / Output Overvoltage  
Warning Limit  
Input / Output Undervoltage  
Protection Limit  
Can only be disabled to a preset  
default value  
5% ( LL - HL )  
Input Overcurrent  
Protection Limit  
5% ( 10 - 133% of FL)  
5% ( 10 - 133% of FL)  
7°C ( Full Range)  
7°C ( Full Range)  
50 µs  
Input Overcurrent  
Warning Limit  
0 to 5.25 A  
Overtemperature Protection  
Limit  
0 to 125°C  
Overtemperature  
Warning Limit  
(51h) OT_WARN_LIMIT  
(60h) TON_DELAY  
0 to 125°C  
Additional time delay to the  
Undervoltage Startup Delay  
Turn on Delay  
0 to 100 ms  
[3] Refer to Digital Supervisor datasheet for complete list of supported commands.  
BCM® Bus Converter  
Page 8 of 23  
Rev 1.4  
05/2015  
vicorpower.com  
800 927.9474