 浏览型号BCM384Y120X1K5AC1的Datasheet PDF文件第2页浏览型号BCM384Y120X1K5AC1的Datasheet PDF文件第3页浏览型号BCM384Y120X1K5AC1的Datasheet PDF文件第4页浏览型号BCM384Y120X1K5AC1的Datasheet PDF文件第5页浏览型号BCM384Y120X1K5AC1的Datasheet PDF文件第7页浏览型号BCM384Y120X1K5AC1的Datasheet PDF文件第8页浏览型号BCM384Y120X1K5AC1的Datasheet PDF文件第9页浏览型号BCM384Y120X1K5AC1的Datasheet PDF文件第10页  
BCM384y120x1K5AC1  
Electrical Specifications (Cont.)  
Specifications apply over all line and load conditions, unless otherwise noted; Boldface specifications apply over the temperature range of -40°C TINTERNAL  
125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.  
Attribute  
Symbol  
Conditions / Notes  
Min  
Typ  
Max  
Unit  
Powertrain (Cont.)  
Effective value at 12 VOUT  
Effective Output capacitance (internal)  
Effective Output capacitance (external)  
COUT_INT  
208  
µF  
µF  
Excessive capacitance may drive module into  
SC protection  
COUT_EXT  
0
1000  
Array Maximum external output  
capacitance  
COUT_AEXT  
COUT_AEXT Max = N * 0.5*COUT_EXT Max  
Powertrain Protection  
Startup into a persistent fault condition.  
292.5  
357.5  
ms  
tAUTO_RESTART  
Non-Latching fault detection given VIN > VIN_UVLO+,  
Module will ignore attempts to re-enable during time off  
Auto Restart Time  
Input overvoltage lockout threshold  
Input overvoltage recovery threshold  
Input overvoltage lockout hysteresis  
Overvoltage lockout response time  
VIN_OVLO+  
VIN_OVLO-  
VIN_OVLO_HYST  
tOVLO  
430  
410  
440  
430  
10  
450  
440  
V
V
V
100  
µs  
From powertrain active  
Soft-Start time  
tSOFT-START  
1
ms  
Fast Current limit protection disabled during Soft-Start  
Output overcurrent trip threshold  
Overcurrent Response Time Constant  
Short circuit protection trip threshold  
Short circuit protection response time  
Overtemperature shutdown threshold  
IOCP  
tOCP  
ISCP  
tSCP  
tOTP  
135  
187  
125  
170  
3.0  
210  
A
ms  
A
Effective internal RC filter  
1
µs  
ºC  
Temperature sensor located inside controller IC  
Powertrain Supervisory Limits  
Input overvoltage lockout threshold  
Input overvoltage recovery threshold  
Input overvoltage lockout hysteresis  
Overvoltage lockout response time  
Input undervoltage lockout threshold  
Input undervoltage recovery threshold  
Input undervoltage lockout hysteresis  
Undervoltage lockout response time  
VIN_OVLO+  
VIN_OVLO-  
VIN_OVLO_HYST  
tOVLO  
420  
405  
434.5  
424  
10.5  
100  
226  
244  
15  
450  
440  
V
V
V
µs  
V
VIN_UVLO-  
VIN_UVLO+  
VIN_UVLO_HYST  
tUVLO  
200  
225  
250  
259  
V
V
100  
µs  
From VIN = VIN_UVLO+ to powertrain active,  
EN floating, (i.e One time Startup delay from  
Undervoltage startup delay  
tUVLO+_DELAY  
20  
ms  
application of VIN to VOUT  
)
Output Overcurrent Trip Threshold  
Overcurrent Response Time Constant  
Overtemperature shutdown threshold  
Undertemperature shutdown threshold  
IOCP  
tOCP  
tOTP  
tUTP  
159  
168  
2
177  
-45  
A
ms  
ºC  
ºC  
Temperature sensor located inside controller IC  
125  
Temperature sensor located inside controller IC  
Startup into a persistent fault condition. Non-Latching  
fault detection given VIN > VIN_UVLO+  
Undertemperature restart time  
tUTP_RESTART  
3
s