欢迎访问ic37.com |
会员登录 免费注册
发布采购

BCM3814B60E15A3CN2 参数 Datasheet PDF下载

BCM3814B60E15A3CN2图片预览
型号: BCM3814B60E15A3CN2
PDF下载: 下载PDF文件 查看货源
内容描述: [DC-DC Unregulated Power Supply Module, 1 Output, 38W, Hybrid, MODULE-13]
分类和应用: 输入元件输出元件
文件页数/大小: 41 页 / 3760 K
品牌: VICOR [ VICOR CORPORATION ]
 浏览型号BCM3814B60E15A3CN2的Datasheet PDF文件第17页浏览型号BCM3814B60E15A3CN2的Datasheet PDF文件第18页浏览型号BCM3814B60E15A3CN2的Datasheet PDF文件第19页浏览型号BCM3814B60E15A3CN2的Datasheet PDF文件第20页浏览型号BCM3814B60E15A3CN2的Datasheet PDF文件第22页浏览型号BCM3814B60E15A3CN2的Datasheet PDF文件第23页浏览型号BCM3814B60E15A3CN2的Datasheet PDF文件第24页浏览型号BCM3814B60E15A3CN2的Datasheet PDF文件第25页  
BCM3814x60E15A3yzz  
Filter Design  
Thermal Considerations  
The VIA package provides effective conduction cooling from either  
of the two module surfaces. Heat may be removed from the top  
surface, the bottom surface or both. The extent to which these  
two surfaces are cooled is a key component for determining the  
maximum power that can be processed by a VIA, as can be seen  
from the specified thermal operating area in Figure 1. Since the  
VIA has a maximum internal temperature rating, it is necessary to  
estimate this internal temperature based on a system-level thermal  
solution. For this purpose, it is helpful to simplify the thermal  
solution into a roughly equivalent circuit where power dissipation  
is modeled as a current source, isothermal surface temperatures  
are represented as voltage sources and the thermal resistances are  
represented as resistors. Figure 22 shows the “thermal circuit” for  
the VIA module.  
A major advantage of BCM systems versus conventional PWM  
converters is that the transformer based BCM does not require  
external filtering to function properly. The resonant LC tank,  
operated at extreme high frequency, is amplitude modulated as  
a function of HI side voltage and LO side current and efficiently  
transfers charge through the isolation transformer. A small amount  
of capacitance embedded in the high voltage side and low voltage  
side stages of the module is sufficient for full functionality and is  
key to achieving power density.  
This paradigm shift requires system design to carefully evaluate  
external filters in order to:  
Guarantee low source impedance:  
To take full advantage of the BCM module’s dynamic response,  
the impedance presented to its HI side terminals must be low  
from DC to approximately 5MHz. The connection of the bus  
converter module to its power source should be implemented  
with minimal distribution inductance. If the interconnect  
inductance exceeds 100nH, the HI side should be bypassed  
with a RC damper to retain low source impedance and stable  
operation. With an interconnect inductance of 200nH, the RC  
damper may be as high as 1µF in series with 0.3Ω. A single  
electrolytic or equivalent low-Q capacitor may be used in place  
of the series RC bypass.  
+
θINT_TOP  
TC_TOP  
θHOU  
s
TC_BOT  
θINT_BOT  
+
PDISS  
Further reduce HI side and/or LO side voltage ripple  
without sacrificing dynamic response:  
s
Given the wide bandwidth of the module, the source response  
is generally the limiting factor in the overall system response.  
Anomalies in the response of the source will appear at the LO  
side of the module multiplied by its K factor.  
Figure 22 — Double-sided cooling VIA thermal model  
In this case, the internal power dissipation is PDISS, θINT_TOP and  
θ
INT_BOT are the thermal resistance characteristics of the VIA module  
Protect the module from overvoltage transients imposed  
by the system that would exceed maximum ratings and  
induce stresses:  
and the top and bottom surface temperatures are represented  
as TC_TOP and TC_BOT. It is interesting to note that the package  
itself provides a high degree of thermal coupling between the  
top and bottom case surfaces (represented in the model by the  
resistor θHOU). This feature enables two main options regarding  
thermal designs:  
The module high side/low side voltage ranges shall not be  
exceeded. An internal overvoltage lockout function prevents  
operation outside of the normal operating HI side range. Even  
when disabled, the powertrain is exposed to the applied voltage  
and the power MOSFETs must withstand it.  
nSingle side cooling: the model of Figure 22 can be simplified by  
calculating the parallel resistor network and using one simple  
thermal resistance number and the internal power dissipation  
curves; an example for bottom side cooling only is shown in  
Figure 23.  
Total load capacitance at the LO side of the BCM module shall not  
exceed the specified maximum. Owing to the wide bandwidth  
and small LO side impedance of the module, low-frequency bypass  
capacitance and significant energy storage may be more densely  
and efficiently provided by adding capacitance at the HI side of  
the module. At frequencies <500kHz the module appears as an  
impedance of RLO between the source and load.  
In this case, θINT can be derived as follows:  
INT_TOP + θHOU) • θINT_BOT  
θINT_TOP + θHOU + θINT_BOT  
(14)  
θINT  
=
Within this frequency range, capacitance at the HI side appears as  
effective capacitance on the LO side per the relationship defined  
in Equation 13.  
CHI_EXT  
K
CLO_EXT  
=
(13)  
2
This enables a reduction in the size and number of capacitors used  
in a typical system.  
BCM® in a VIA Package  
Page 21 of 41  
Rev 2.0  
02/2018  
 复制成功!