BCM352x125y300A00
Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TJ ≤ 125°C (T-Grade); all other specifications are at TJ = 25ºC unless otherwise noted.
Attribute
Symbol
Conditions / Notes
PC
Min
Typ
Max
Unit
PC voltage (operating)
PC voltage (enable)
VPC
VPC_EN
VPC_DIS
IPC_EN
4.7
2
5
5.3
3
V
V
2.5
PC voltage (disable)
1.95
300
5
V
PC source current (start up)
PC source current (operating)
PC internal resistance
50
2
100
3.5
µA
mA
kΩ
pF
pF
kΩ
Hz
µs
IPC_OP
RPC_SNK
CPC_INT
CPC_EXT
RPC
Internal pull down resistor
50
150
400
1000
1000
PC capacitance (internal)
PC capacitance (external)
External PC resistance
PC external toggle rate
PC to VOUT with PC released
PC to VOUT, disable PC
External capacitance delays PC enable time
Connected to –VIN
50
RPC_TOG
TON2
1
VIN = 352V, pre-applied, CPC = 0, COUT = 0
VIN = 352V, pre-applied, CPC = 0, COUT = 0
TM
50
100
4
150
10
TPC_DIS
µs
TM accuracy
ACTM
ATM
-5
+5
ºC
mV / ºC
µA
TM gain
10
40
TM source current
TM internal resistance
External TM capacitance
TM voltage ripple
ITM
100
50
RTM_SNK
CTM
25
50
kΩ
50
pF
VTM_PP
CTM = 0µF, VIN = 365V, POUT = 300W
100
200
mV
BCM® Bus Converter
Page 6 of 21
Rev 2.0
08/2016
vicorpower.com
800 927.9474