BCM352x125y300A00
Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TJ ≤ 125°C (T-Grade); all other specifications are at TJ = 25ºC unless otherwise noted.
Attribute
Symbol
Conditions / Notes
Protection
Min
Typ
Max
Unit
Input overvoltage lockout threshold
Input overvoltage recovery threshold
VIN_OVLO+
VIN_OVLO-
380
366
387
383
400
390
V
V
Input undervoltage recovery
threshold
VIN_UVLO+
VIN_UVLO-
295
270
310
325
V
V
Input undervoltage lockout
threshold
295
42
325
52
Output overcurrent trip threshold
IOCP
ISCP
VIN = 352V, 25ºC
32
60
A
A
Short circuit protection trip threshold
Short circuit protection response
time
TSCP
1.2
µs
Thermal shutdown threshold
TJ_OTP
125
130
135
°C
500
450
400
350
300
250
200
150
100
50
0
11.40
11.90
12.40
12.90
Output Voltage (V)
P (ave)
P (pk) < 10ms
Figure 1 — Safe operating area
BCM® Bus Converter
Page 5 of 21
Rev 2.0
08/2016
vicorpower.com
800 927.9474