Detailed Hold Over Specifications (us)
Holdover Capability - MD-0110-DXJ-TCXO-10M0000000
Holdover Time
1 minute
ΔT=2 ˚C
ΔT=10 ˚C
ΔT=20 ˚C
ΔT=30 ˚C
ΔT=45 ˚C9
0.6
2
2.1
10
4
6
10
45
5 minutes
10 minutes
30 minutes
1 hour
20
30
4.9
15
32
20
40
60
85
60
120
240
175
350
260
520
120
Holdover Capability - MD-0112-DXJ-HPTC-10M0000000
Holdover Time
1 minute
ΔT=2 ˚C
0.25
0.75
1.5
ΔT=10 ˚C
ΔT=20 ˚C
ΔT=30 ˚C
ΔT=45 ˚C9
0.5
2.1
4.3
13
1
4
1.2
5.5
10.8
33
1.7
8
5 minutes
10 minutes
30 minutes
1 hour
8
16
55
120
4.8
23
47
12
27
66
Holdover Capability - MD-0111-DXJ-EMXO-10M0000000
Holdover Time
30 minutes
1 hour
ΔT=2 ˚C
6.5
ΔT=10 ˚C
31
ΔT=20 ˚C
60
ΔT=30 ˚C
95
ΔT=45 ˚C9
140
12.5
52
60
120
180
270
4 hours
250
480
725
1090
8 hours
105
490
970
1450
4380
2170
24 hours
340
1500
2950
6530
Holdover Capability - MD-0111-DXJ-DAEM-10M0000000
Holdover Time
30 minutes
1 hour
ΔT=2 ˚C
ΔT=10 ˚C
ΔT=20 ˚C
ΔT=30 ˚C
12.3
25
ΔT=45 ˚C9
1
2
4.5
8.7
34
8.2
17
19
37
4 hours
8.5
20
90
70
100
150
295
920
8 hours
75
140
440
200
24 hours
240
630
Holdover Capability - MD-0110-DXJ-OCXO-10M0000000
Holdover Time
30 minutes
1 hour
ΔT=2 ˚C
ΔT=10 ˚C
ΔT=20 ˚C
ΔT=30 ˚C
ΔT=45 ˚C9
0.45
0.9
3.6
8
1.8
4
3.4
6.6
27
5
10
40
80
250
7.4
15
4 hours
14
30
100
60
8 hours
55
120
360
24 hours
32
170
Holdover Capability - MD-0110-DXJ-DAOC-10M0000000
Holdover Time
30 minutes
1 hour
ΔT=2 ˚C
ΔT=10 ˚C
ΔT=20 ˚C
ΔT=30 ˚C
ΔT=45 ˚C9
0.12
.24
1
0.2
0.4
1.6
3.7
21
0.3
0.5
2.3
5
0.35
1
0.5
1
4 hours
3
3.9
8.2
32
8 hours
4.5
18
3.5
25
24 hours
23
Holdover Capability - MD-0110-DXJ-DOCX-10M0000000
Holdover Time
30 minutes
1 hour
ΔT=2 ˚C
0.05
.09
ΔT=10 ˚C
ΔT=20 ˚C
0.19
ΔT=30 ˚C
0.27
0.54
2.2
ΔT=45 ˚C9
0.11
0.21
0.91
2
0.4
0.77
3.1
6.8
23
0.38
4 hours
0.4
1.54
8 hours
1.03
5.9
3.4
4.7
24 hours
9
12.8
17
5
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com