17–24GHz Down Converter
Typical Measured Performances
CHR3663-QEG
Tamb = +25°C, VD = VDL = 4.5V, VGL = -0.4V, VGM = -0.7V, P_LO = 0dBm
These values are representative of onboard measurements (on connector access planes) as
defined on the drawing 97625 page 16. The board losses are estimated from 1.5 to 2.0dB in
the frequency range.
16
14
12
10
8
Conversion Gain (dB)
6
4
2
0
-2
-4
-6
-8
-10
-12
-14
-16
17
18
19
20
21
22
23
24
25
26
RF Frequency (GHz)
Gcmax_SUP@2GHz
Gcmax_SUP@3,5GHz
Gcmin_SUP@2GHz
Gcmin_SUP@3,5GHZ
Figure 1: Conversion Gain in Supradyne Mode versus Frequency
F_RF = 2xF_LO+F_IF, F_IF = 2.0 & 3.5GHz, GC2 = GC3 = -1.5 & 0.5V
16
14
12
10
8
Conversion Gain (dB)
6
4
2
0
-2
-4
-6
-8
-10
-12
-14
-16
17
18
19
20
21
22
23
24
25
26
RF Frequency (GHz)
Gcmax_INF@2GHz
Gcmax_INF@3,5GHz
Gcmin_INF@2GHz
Gcmin_INF@3,5GHz
Figure 2: Conversion Gain in Infradyne Mode versus Frequency
F_RF = 2xF_LO-F_IF, F_IF = 2.0 & 3.5GHz, GC2 = GC3 = -1.5 & 0.5V
Ref. : DSCHR3663-QEG1192 - 11 Jul 11
5/18
Specifications subject to change without notice
Route Départementale 128, BP46 - 91401 ORSAY Cedex - FRANCE
Tel.: +33 (0) 1 69 33 03 08 - Fax: +33 (0) 1 69 33 03 09