K-band RX
CHR2411-QDG
Typical QFN measurements on board 95541 (QFN plan)
Conversion Gain vs Frequency
PLO= 0dBm
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
22
22,5
23
23,5
24
24,5
Conversion Gain (dB)
-40°C
25°C
100°C
25
25,5
26
Conversion gain vs RF Input Power
PLO= 0dBm FLO=24.25GHz
30
29
28
27
26
-40°C
25
24
23
25°C
22
21
20
19
100°C
18
17
16
15
-40 -38 -36 -34 -32 -30 -28 -26 -24 -22 -20 -18 -16 -14 -12
RF Input power (dBm)
Ref. : DSCHR2411QDG6174 - 23 Jun 06
Conversion Gain (dB)
3/8
Specifications subject to change without notice
Route Départementale 128 , B.P.46 - 91401 ORSAY Cedex - FRANCE
Tel.: +33 (0)1 69 33 03 08 - Fax : +33 (0)1 69 33 03 09