TRUMPower
PFC 130 WATT POWER SUPPLIES
DESCRIPTION
TFC130 SERIES
(LVD)
The TFC130 series incorporates creative high
efficiency circuitry, high power density (6.94
Watts/in3) and active Power Factor Correction
(PFC) to meet the requirements of data
networking, computing and telecommunication
systems. Some models with one or two outputs
adjustable between 5V and 24V intend to suit
more applications.
(MULTIPLE OUTPUT)
RoHS
FEATURES
‧ EN61000-3-2 class A and D compliant
‧ Power factor 0.98 typical
‧ Very compact size, 3″×5″×1.2″
‧ Overvoltage protection
‧ Short circuit protection
Safety Standard Approvals:
‧ Remote sense on 3.3V output
‧ Power Good/Power Fail Detect Signal
‧ Up to five DC outputs
UL 60950 3rd
CSA C22.2 No. 60950 3rd
‧ All outputs well regulated
‧ Compliant with RoHS requirements
TÜV EN60950-1
INPUT SPECIFICATIONS
Input voltage:
Input frequency:
Input current:
90 to 264VAC
ENVIRONMENTAL SPECIFICATIONS
Operating temperature: -10ºC to +60ºC
47 to 63Hz
2.1A(rms)max. for 115VAC
1.1A(rms)max. for 230VAC
0.3mA max. @ 115VAC, 60Hz
0.6mA max. @ 230VAC, 50Hz
Storage temperature:
Relative humidity:
Derating:
-40ºC to +85ºC
5% to 95% non-condensing
Derate from 100% at +40ºC
linearly to 50% at +60ºC
10 CFM total forced air
from two 40mm diameter
fans or the like is required
and provided by user.
Earth leakage current:
(Touch Current)
Cooling:
OUTPUT SPECIFICATIONS
Output voltage/current: See Rating Chart
Ripple and noise:
65mV peak to peak on V1,1%
peak to peak on other outputs
GENERAL SPECIFICATIONS
Overvoltage protection: Provided on V0 & V1; set at
112–132% of its nominal
Switching frequency: 100KHz ±10KHz
Power factor:
Efficiency:
0.98 typical
output voltage
75% typical
Hold-up time:
Line regulation:
Inrush current:
15 msec minimum at 115VAC
±0.5% maximum at full load
35 amps @ 115VAC or 70 amps
@ 230VAC at 25ºC cold start
3000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
200,000 hours minimum
Overcurrent protection: All outputs protected to short
circuit conditions
Temperature coefficient: All outputs ±0.04/ºC maximum
Transient response:
Maximum excursion of 4%
or better on all models,
recovering to 1% of final
value within 500µs after
a 25% step load change
Withstand voltage:
MTBF:
EMC Performance (EN55024)
PG/PFD signal:
TTL logic high for normal
operation and TTL logic low
upon loss of input power.
This signal appears at least
10ms prior to master output
dropping 5% below its
EN55022:
FCC Part 15
VCCI:
Class B conducted, class A radiated
Class B conducted, class A radiated
Class B conducted, class A radiated
Harmonic distortion, class A and D
Line flicker
ESD, ±8KV air and ±4KV contact
Radiated immunity, 3V/m
EN61000-3-2:
EN61000-3-3:
EN61000-4-2:
EN61000-4-3:
EN61000-4-4:
EN61000-4-5:
EN61000-4-6:
EN61000-4-8:
EN61000-4-11:
nominal value. This signal
also provides a minimum
delay of 100ms after master
output is within regulation
Fast transient/burst, ±1KV
Surge, ±1KV diff, ±2KV com.
Conducted immunity, 3Vrms
Magnetic field immunity, 1A/m
Voltage dips, 30% reduction for
500ms and >95% reduction for 10ms
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com