 浏览型号TMCM-1141-TMCL的Datasheet PDF文件第13页浏览型号TMCM-1141-TMCL的Datasheet PDF文件第14页浏览型号TMCM-1141-TMCL的Datasheet PDF文件第15页浏览型号TMCM-1141-TMCL的Datasheet PDF文件第16页浏览型号TMCM-1141-TMCL的Datasheet PDF文件第18页浏览型号TMCM-1141-TMCL的Datasheet PDF文件第19页浏览型号TMCM-1141-TMCL的Datasheet PDF文件第20页浏览型号TMCM-1141-TMCL的Datasheet PDF文件第21页  
TMCM-1141 Hardware Manual (Rev. 1.06 / 2015-JAN-09)  
17  
4 Motor driver current  
The on-board stepper motor driver operates current controlled. The driver current may be programmed in  
software in two ranges (low current range up-to 1.1A RMS and high current range up-to 2A RMS) with 32  
effective scaling steps in hardware for each range.  
Please note: the high current range is available with hardware revision V1.3, only and should not be  
activated / used with hardware revision V1.2! The high current range should not be used with motor  
currents above 2A RMS this will violate specification of the module - please note limitations at the  
end of this chapter!  
Explanation of different columns in table below:  
Motor current  
setting in  
software  
(TMCL)  
These are the values for TMCL axis parameter 6 (motor run current) and 7 (motor  
standby current). They are used to set the run / standby current using the following  
TMCL commands:  
SAP 6, 0, <value> // set run current  
SAP 7, 0, <value> // set standby current  
(read-out value with GAP instead of SAP. Please see separate TMCM-1141 firmware  
manual for further information)  
Range setting  
in software  
(TMCL)  
This is the value for TMCL axis parameter 179 (Vsense). This value defines the current  
range. This value can be set using the following TMCL command:  
SAP 179, 0, <value> // = 0 high current range  
// = 1 low current range  
For <value>either 0 (high current range) or 1 (low current range) is supported (see  
table) since hardware revision V1.3. For hardware revision V1.2 this parameter should  
not be changed to any value other than “1” (low current range).  
(read-out value with GAP instead of SAP. Please see separate TMCM-1141 firmware  
manual for further information)  
Motor current  
IRMS [A]  
Resulting motor current based on range and motor current setting  
Motor current  
setting in  
software (TMCL)  
0..7  
Range setting  
in software  
Current  
scaling step  
Motor  
current  
ICOIL_PEAK [A]  
0.052  
Motor  
current  
ICOIL_RMS [A]  
(TMCL)  
(CS)  
0
1
2
3
4
5
6
7
8
9
10  
1
1
1
1
1
1
1
1
1
1
1
0.036  
8..15  
16..23  
24..31  
32..39  
40..47  
48..55  
56..63  
64..71  
0.103  
0.155  
0.206  
0.258  
0.309  
0.361  
0.413  
0.464  
0.073  
0.109  
0.146  
0.182  
0.219  
0.255  
0.292  
0.328  
0.365  
0.401  
72..79  
80..87  
0.516  
0.567  
www.trinamic.com  