TMC8462 Datasheet • Document Revision V1.4 • 2018-May -09
72 / 204
6.4.8.4 PDI Error Counter (0x030D)
Bit
Description
ECAT
PDI
Reset Value
7:0
PDI Error counter (counting is stopped when r/
0xFF is reached). Counts if a PDI access has an w(clr)
interface error.
r/-
Table 47: Register 0x030D (PDI Err Cnt)
Note
Error Counter 0x030D and Error Code 0x030E are cleared if error counter 0x030D
is written. Write value is ignored (write 0).
6.4.8.5 PDI Error Code (0x030E)
Bit
Description
ECAT
PDI
Reset Value
SPI access which caused last PDI Error.
Cleared if register 0x030D is written.
r/-
r/-
2:0
Number of SPI clock cycles of whole access r/-
(modulo 8)
r/-
3
Busy violation during read access
Read termination missing
r/-
r/-
r/-
r/-
r/-
r/-
r/-
r/-
4
5
Access continued after read termination byte
SPI command CMD[2:1]
7:6
Table 48: Register 0x030E (PDI Err Code)
Note
Error Counter 0x030D and Error Code 0x030E are cleared if error counter 0x030D
is written. Write value is ignored (write 0).