TMC5160 DATASHEET (Rev. 1.08 / 2018-NOV-19)  
38  
VELOCITY DEPENDENT DRIVER FEATURE CONTROL REGISTER SET (0X10…0X1F)  
R/W  
Addr  
n
Register  
Description / bit names  
This is the upper velocity for stealthChop voltage PWM mode.  
TSTEP TPWMTHRS  
W
0x13  
20 TPWMTHRS  
-
stealthChop PWM mode is enabled, if configured  
dcStep is disabled  
-
This is the lower threshold velocity for switching on smart  
energy coolStep and stallGuard feature. (unsigned)  
Set this parameter to disable coolStep at low speeds, where it  
cannot work reliably. The stop on stall function (enable with  
sg_stop when using internal motion controller) and the stall  
output signal become enabled when exceeding this velocity. In  
non-dcStep mode, it becomes disabled again once the velocity  
falls below this threshold.  
W
0x14  
20 TCOOLTHRS  
TCOOLTHRS TSTEP THIGH:  
-
coolStep is enabled, if configured  
-
stealthChop voltage PWM mode is disabled  
TCOOLTHRS TSTEP  
-
-
Stop on stall is enabled, if configured  
Stall output signal (DIAG0/1) is enabled, if configured  
This velocity setting allows velocity dependent switching into  
a different chopper mode and fullstepping to maximize torque.  
(unsigned)  
The stall detection feature becomes switched off for 2-3  
electrical periods whenever passing THIGH threshold to  
compensate for the effect of switching modes.  
TSTEP THIGH:  
W
0x15  
20 THIGH  
-
coolStep is disabled (motor runs with normal current  
scale)  
-
-
stealthChop voltage PWM mode is disabled  
If vhighchm is set, the chopper switches to chm=1  
with TFD=0 (constant off time with slow decay, only).  
If vhighfs is set, the motor operates in fullstep mode  
and the stall detection becomes switched over to  
dcStep stall detection.  
-
Microstep velocity time reference t for velocities: TSTEP = fCLK / fSTEP  
www.trinamic.com  