TMC4671 Datasheet IC Version V1.00 | Document Revision V1.04 2018-Dec-11  
50 / 157  
The transfer function needs to be transformed to time discrete domain by Z-Transformation and coe-  
cients need to be normalized. This is done by the following equations.  
b_2_z = (b_0_cont · T2 + 2 · b_1_cont · T + 4 · b_2_cont)/(T2 2 · a_1_cont · T + 4 · a_2_cont)  
b_1_z = (2 · b_0_cont · T2 8 · b_2_cont)/(T2 2 · a_1_cont · T + 4 · a_2_cont)  
b_0_z = (b_0_cont · T2 2 · b_1_cont · T + 4 · b_2_cont)/(T2 2 · a_1_cont · T + 4 · a_2_cont)  
a_2_z = (T2 + 2 · a_1_cont · T + 4 · a_2_cont)/(T2 2 · a_1_cont · T + 4 · a_2_cont)  
a_1_z = (2 · T2 8 · a_2_cont)/(T2 2 · a_1_cont · T + 4 · a_2_cont)  
b_0 = round(b_0_z · 229)  
(26)  
(27)  
(28)  
(29)  
(30)  
(31)  
(32)  
(33)  
(34)  
(35)  
b_1 = round(b_1_z · 229)  
b_2 = round(b_2_z · 229)  
a_1 = round(a_1_z · 229)  
a_2 = round(a_2_z · 229)  
while T is the sampling time according to PWM_MAX_COUNT  
variables.  
·
10 ns and variables with index z are auxiliary  
There are four biquad lters in the control structure. Figure 29 illustrates their placement in the control  
structure.  
Figure 29: Biquad Filters  
The biquad lter for the position target value is intended to be used as a low-pass lter for smoothening  
position input to the control structure. It is evaluated in every PWM cycle, or down-sampled according to  
the down-sampling factor for the velocity and position controllers. After powering on it is disabled.  
The biquad lter for the ux target value is also intended to be used as a low-pass lter for input values  
from the users microcontroller. Sampling frequency is xed to the PWM frequency.  
The biquad lter for the torque target value can be used as a low-pass lter for bandwidth limitation  
and noise suppression. Moreover, it can be designed to suppress a resonance or anti-resonance. Same  
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany  
Terms of delivery and rights to technical change reserved.  
Download newest version at www.trinamic.com  