TMC262 DATASHEET (Rev. 2.07 / 2013-FEB-14)  
9
4 stallGuard2 Load Measurement  
stallGuard2 provides an accurate measurement of the load on the motor. It can be used for stall  
detection as well as other uses at loads below those which stall the motor, such as coolStep load-  
adaptive current reduction. (stallGuard2 is a more precise evolution of the earlier stallGuard  
technology.)  
The stallGuard2 measurement value changes linearly over a wide range of load, velocity, and current  
settings, as shown in Figure 4.1. At maximum motor load, the value goes to zero or near to zero. This  
corresponds to a load angle of 90° between the magnetic field of the coils and magnets in the rotor.  
This also is the most energy-efficient point of operation for the motor.  
1000  
900  
stallGuard2  
Start value depends  
on motor and  
operating conditions  
800  
700  
600  
500  
400  
300  
200  
100  
0
reading  
stallGuard value reaches zero  
and indicates danger of stall.  
This point is set by stallGuard  
threshold value SGT.  
Motor stalls above this point.  
Load angle exceeds 90° and  
available torque sinks.  
10  
20  
30  
40  
50  
60  
70  
80  
90 100  
motor load  
(% max. torque)  
Figure 4.1 stallGuard2 load measurement SG as a function of load  
Two parameters control stallGuard2 and one status value is returned.  
Parameter  
Description  
Setting  
Comment  
SGT  
7-bit signed integer that sets the stallGuard2 0  
threshold level for asserting the SG_TST output  
indifferent value  
+1… +63  
-1… -64  
less sensitivity  
and sets the optimum measurement range for  
readout. Negative values increase sensitivity,  
and positive values reduce sensitivity so more  
torque is required to indicate a stall. Zero is a  
good starting value. Operating at values below -  
10 is not recommended.  
higher sensitivity  
SFILT  
Mode bit which enables the stallGuard2 filter for 0  
standard mode  
filtered mode  
more precision. If set, reduces the measurement  
frequency to one measurement per four  
fullsteps. If cleared, no filtering is performed.  
1
Filtering  
compensates  
for  
mechanical  
asymmetries in the construction of the motor,  
but at the expense of response time. Unfiltered  
operation is recommended for rapid stall  
detection. Filtered operation is recommended  
for more precise load measurement.  