30  
TMC211 DATASHEET (V. 1.04 / January 7, 2005)  
6.9.2 Writing Frame Type#1 (2 or 4 bytes)  
General purpose 2 or 4 data bytes writing frame with a dynamically assigned identifier. This type is  
used to provide 2 or 4 bytes of data to the slave nodes. When <Broad> is set to zero, broadcasting is  
active and the command is valid for all slave nodes. When <Broad> is one the command is only valid  
for one slave node whose physical address corresponds to the one provided by the writing frame.  
A writing frame of 2 bytes issues only a defined command to the slave node(s), e.g. HardStop  
command. Whereas a writing frame of 4 bytes issues a command and 2 bytes of data to the slave  
node(s), e.g. SetPosition command.  
ID  
ID [7:0]  
Data1  
CMD [6:0]  
Data2  
Data3  
Data4  
1
B
Physical  
Address  
Identifier  
Command  
Parameters  
6.9.3 Writing Frame Type#2 (2, 4 or 8 bytes)  
2, 4 or 8 data bytes writing frame with an identifier dynamically assigned to a particular application  
command, regardless of the physical address of the circuit. e.g. SetPositionShort command.  
ID  
Data1  
Data2  
AD [3:0]  
ID [5:0] pp  
B
Dynamic  
Identifier  
physical  
address  
Parameter [10:0]  
6.9.4 Writing Frame Type#3 (2 bytes)  
2 data bytes writing frame with an identifier dynamically assigned to a particular slave node and  
application command. This type of frame requires that there are as many dynamically assigned  
identifiers as there are TMC211 circuits connected to the LIN bus using this command.  
ID  
Data1  
Data2  
ID [5:0] pp  
Dynamic  
Identifier  
Parameter [15:0]  
6.9.5 Writing Frame Type#4 (8 bytes)  
8 data bytes writing frame with fixed identifier 0x3C. The structure is similar to type#1 but uses the  
reserved identifier 0x3C. Using a reserved identifier followed by a particular application command will  
expand the amount of possible LIN commands.  
ID  
0x3C  
Data1  
0x80  
Data2  
CMD [6:0]  
Data3  
Data4  
Data5  
Data6  
Data7  
Data8  
00  
1
B
physical  
address  
fixed identifier  
AppCMD  
Command  
Parameters send from LIN master to LIN slave node  
Copyright © 2004-2005 TRINAMIC Motion Control GmbH & Co. KG  
 复制成功!