ULN2002A, ULN2003A, ULN2003AI, ULN2004A
ULQ2003A, ULQ2004A
SLRS027J –DECEMBER 1976–REVISED JUNE 2010
www.ti.com
ELECTRICAL CHARACTERISTICS
TA = –40°C to 105°C
ULN2003AI
PARAMETER
TEST FIGURE
TEST CONDITIONS
UNIT
MIN
TYP
MAX
IC = 200 mA
2.7
2.9
3
VI(on)
On-state input voltage
Figure 6
Figure 5
VCE = 2 V
IC = 250 mA
IC = 300 mA
IC = 100 mA
IC = 200 mA
IC = 350 mA
II = 0
V
V
II = 250 mA,
II = 350 mA,
II = 500 mA,
VCE = 50 V,
IF = 350 mA
VCE = 50 V,
VI = 3.85 V
VR = 50 V
VI = 0,
0.9
1
1.2
1.4
1.7
100
2.2
VCE(sat)
Collector-emitter saturation voltage
1.2
ICEX
VF
II(off)
II
Collector cutoff current
Clamp forward voltage
Off-state input current
Input current
Figure 1
Figure 8
Figure 3
Figure 4
Figure 7
mA
V
1.7
65
IC = 500 mA
30
mA
mA
mA
pF
0.93
1.35
100
25
IR
Clamp reverse current
Input capacitance
Ci
f = 1 MHz
15
ELECTRICAL CHARACTERISTICS
over recommended operating conditions (unless otherwise noted)
ULQ2003A
ULQ2004A
TEST
FIGURE
PARAMETER
TEST CONDITIONS
UNIT
MIN
TYP MAX
MIN
TYP MAX
IC = 125 mA
IC = 200 mA
IC = 250 mA
IC = 275 mA
IC = 300 mA
IC = 350 mA
IC = 100 mA
IC = 200 mA
IC = 350 mA
II = 0
5
6
2.7
2.9
VI(on)
On-state input voltage
Figure 6
VCE = 2 V
V
7
8
3
II = 250 mA,
II = 350 mA,
II = 500 mA,
VCE = 50 V,
0.9
1
1.2
1.4
1.7
100
0.9
1
1.1
1.3
1.6
50
Collector-emitter
saturation voltage
VCE(sat)
Figure 5
V
1.2
1.2
Figure 1
Figure 2
ICEX
Collector cutoff current
VCE = 50 V,
TA = 70°C
II = 0
100
500
2
mA
VI = 6 V
VF
Clamp forward voltage
Off-state input current
Figure 8
Figure 3
IF = 350 mA
1.7
65
2.3
1.7
65
V
VCE = 50 V,
TA = 70°C,
II(off)
IC = 500 mA
50
mA
VI = 17 V
0.93
1.35
II
Input current
Figure 4
Figure 7
0.35
1
0.5 mA
1.45
TA = 25°C
f = 1 MHz
100
100
25
50
100
25
IR
Ci
Clamp reverse current
Input capacitance
VR = 50 V
VI = 0,
mA
15
15
pF
6
Submit Documentation Feedback
Copyright © 1976–2010, Texas Instruments Incorporated
Product Folder Link(s): ULN2002A ULN2003A ULN2003AI ULN2004A ULQ2003A ULQ2004A