TLC5970  
www.ti.com  
SBVS140 MARCH 2010  
Status Information Data (SID) Readout Register (Register Address = 1010b)  
When any data are written to this register address, the status of five error detections are loaded to the lower 36  
bits in the 40-bit shift register from this readout register (register address = 1010b). The higher 4-bit data in the  
40-bit shift register are not changed from 1010b. The loaded data can be readout from SDTY and SDTZ and  
syncronized by the shift clock generated from SCKA and SCKB. The data bit assignments are are shown in  
Table 18 and Figure 35.  
Table 18. SID Readout Register Bit Assignment  
BIT NUMBER  
BIT NAME  
DESCRIPTION  
LED open detection (LOD) error flag  
0 = All OUTn are either connected to the LED lamp or are not  
connected to the LED lamp. When all OUTn are not connected to  
LED lamp, the OVP flag is set to '1'.  
1 = One or two OUTn are not connected to the LED lamp. This bit is  
set to '1' when the voltage of OUTn connected to the LED lamp is  
greater than approximately 4 V. Also, this bit is set to '1' when the  
SWOFF pin is connected to VREG.  
0
LOD  
Short-Circuit Protection (SCP) error flag  
0 = The buck converter is operating normally. Also, this bit is set to  
'0' when SWOFF is connected to VREG.  
1 = The buck converter is not operated by the SCP.  
1
2
SCP  
OVP  
Overvoltage Protection (OVP) flag  
0 = The buck converter is operating normally. Also, this bit is set to  
'0' when SWOFF is connected to VREG.  
1 = The buck converter is not operated by the OVP.  
Pre-Thermal Shutdown (PTD) log  
0 = The LED driver has been in normal operation after the previous  
readout register reading.  
3
PTD  
1 = The LED driver has stopped operating due to the device  
temperature exceeding the PTD detect temperature after the  
previous readout register reading. This log is held until these register  
data are readout.  
Thermal Shutdown (TSD) log  
0 = The buck converter/LED driver/interface has been in normal  
operation after the previous readout register reading.  
1 = The buck converter/LED driver/interface has stopped operating  
due to the device temperature exceeding the TSD detect  
temperature after the previous readout register reading. This flag is  
held until these register data are readout.  
4
TSD  
35-5  
TI reserved data (31-bit data, no fixed data)  
Status Information Data (SID) Read Out Register  
MSB  
35  
LSB  
0
34  
TI  
6
5
4
3
2
1
TI  
TI  
TI  
TSD  
Log  
PTD  
Log  
OVP  
Flag  
SCP  
Flag  
LOD  
Flag  
¼
Reserved Reserved  
Bit 30  
Bit 29  
Reserved Reserved  
Bit 1 Bit 0  
Figure 35. SID Readout Register Bit Assignment  
Copyright © 2010, Texas Instruments Incorporated  
Submit Documentation Feedback  
43  
Product Folder Link(s): TLC5970  
 
 