欢迎访问ic37.com |
会员登录 免费注册
发布采购

TLC5620CN 参数 Datasheet PDF下载

TLC5620CN图片预览
型号: TLC5620CN
PDF下载: 下载PDF文件 查看货源
内容描述: 翻两番8位数字 - 模拟转换器 [QUADRUPLE 8-BIT DIGITAL-TO-ANALOG CONVERTERS]
分类和应用: 转换器数模转换器光电二极管
文件页数/大小: 14 页 / 217 K
品牌: TI [ TEXAS INSTRUMENTS ]
 浏览型号TLC5620CN的Datasheet PDF文件第1页浏览型号TLC5620CN的Datasheet PDF文件第2页浏览型号TLC5620CN的Datasheet PDF文件第4页浏览型号TLC5620CN的Datasheet PDF文件第5页浏览型号TLC5620CN的Datasheet PDF文件第6页浏览型号TLC5620CN的Datasheet PDF文件第7页浏览型号TLC5620CN的Datasheet PDF文件第8页浏览型号TLC5620CN的Datasheet PDF文件第9页  
TLC5620C, TLC5620I
QUADRUPLE 8-BIT DIGITAL-TO-ANALOG CONVERTERS
SLAS081E – NOVEMBER 1994 – REVISED NOVEMBER 2001
detailed description
The TLC5620 is implemented using four resistor-string DACs. The core of each DAC is a single resistor with
256 taps, corresponding to the 256 possible codes listed in Table 1. One end of each resistor string is connected
to the GND terminal and the other end is fed from the output of the reference input buffer. Monotonicity is
maintained by use of the resistor strings. Linearity depends upon the matching of the resistor elements and upon
the performance of the output buffer. Since the inputs are buffered, the DACs always present a high-impedance
load to the reference source.
Each DAC output is buffered by a configurable-gain output amplifier that can be programmed to times 1 or times
2 gain.
On power up, the DACs are reset to CODE 0.
Each output voltage is given by:
V (DACA|B|C|D)
O
+
REF
CODE
256
(1
)
RNG bit value)
where CODE is in the range 0 to 255 and the range (RNG) bit is 0 or 1 within the serial control word.
Table 1. Ideal Output Transfer
D7
0
0
0
1
1
D6
0
0
1
0
1
D5
0
0
1
0
1
D4
0
0
1
0
1
D3
0
0
1
0
1
D2
0
0
1
0
1
D1
0
0
1
0
1
D0
0
1
1
0
1
OUTPUT VOLTAGE
GND
(1/256)
×
REF (1+RNG)
(127/256)
×
REF (1+RNG)
(128/256)
×
REF (1+RNG)
(255/256)
×
REF (1+RNG)
data interface
With LOAD high, data is clocked into the DATA terminal on each falling edge of CLK. Once all data bits have
been clocked in, LOAD is pulsed low to transfer the data from the serial input register to the selected DAC as
shown in Figure 1. When LDAC is low, the selected DAC output voltage is updated when LOAD goes low. When
LDAC is high during serial programming, the new value is stored within the device and can be transferred to
the DAC output at a later time by pulsing LDAC low as shown in Figure 2. Data is entered most significant bit
(MSB) first. Data transfers using two 8-clock cycle periods are shown in Figures 3 and 4.
CLK
tsu(DATA-CLK)
tv(DATA-CLK)
DATA
A1
A0
RNG
D7
D6
D5
D4
D3
tsu(LOAD-CLK)
D2
D1
D0
tsu(CLK-LOAD)
LOAD
tw(LOAD)
DAC Update
Figure 1. LOAD-Controlled Update (LDAC = Low)
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
3