SLLS405A – DECEMBER 1999 – REVISED AUGUST 2000  
functional description (continued)  
auto-CTS  
The transmitter circuitry checks CTS before sending the next data byte. When CTS is active, the transmitter  
sends the next byte. To stop the transmitter from sending the following byte. CTS must be deasserted before  
the middle of the last stop bit that is currently being sent. The auto-CTS function reduces interrupts to the host  
system. When flow control is enabled, the CTS state changes and need not trigger host interrupts because the  
device automatically controls its own transmitter. Without auto-CTS, the transmitter sends any data present in  
the transmit FIFO and a receiver overrun error can result. Figure 2 shows CTS functional timing, and Figure 3  
shows an example of autoflow control.  
TX  
Start  
Byte 0–7  
Stop  
Start  
Byte 0–7  
Stop  
CTS  
NOTES: A. When CTS is low, the transmitter keeps sending serial data out  
B. When CTS goes high before the middle of the last stop bit of the current byte, the transmitter finishes sending the current byte but  
it does not send the next byte.  
C. When CTS goes from high to low, the transmitter begins sending data again.  
Figure 2. CTS Functional Timing  
UART 1  
UART 2  
Serial to  
Parallel  
Parallel to  
Serial  
RX  
TX  
RX  
TX  
FIFO  
FIFO  
Flow  
RTS CTS  
Flow  
Control  
Control  
D7–D0  
D7–D0  
Parallel to  
Serial  
Serial to  
Parallel  
TX  
RX  
TX  
FIFO  
RX  
FIFO  
Flow  
Control  
CTS RTS  
Flow  
Control  
Figure 3. Autoflow Control (Auto-RTS and Auto-CTS) Example  
6