SLOS556B – NOVEMBER 2008 – REVISED NOVEMBER 2009
www.ti.com
RECOMMENDED OPERATING CONDITIONS (continued)
MIN
T
J
(1)
NOM
8
MAX
125
UNIT
°C
Ω
μH
Operating junction temperature range
Load impedance
Output-filter inductance
Output filter: L = 15
μH,
C = 680 nF.
Minimum output inductance under
short-circuit condition
0
6
10
R
L
(BTL)
L
O
(BTL)
(1)
Continuous operation above the recommended junction temperature may result in reduced reliability and/or lifetime of the device.
PWM OPERATION AT RECOMMENDED OPERATING CONDITIONS
PARAMETER
Output sample rate
TEST CONDITIONS
11.025/22.05/44.1-kHz data rate ±2%
48/24/12/8/16/32-kHz data rate ±2%
VALUE
352.8
384
UNIT
kHz
8
Copyright © 2008–2009, Texas Instruments Incorporated
Product Folder Link(s):