SCAS218U – JANUARY 1993 – REVISED FEBRUARY 2010
www.ti.com
RECOMMENDED OPERATING CONDITIONS
(1)
T
A
= 25°C
MIN
V
CC
Supply voltage
Operating
Data retention only
V
CC
= 1.65 V to 1.95 V
V
IH
High-level input voltage
V
CC
= 2.3 V to 2.7 V
V
CC
= 2.7 V to 3.6 V
V
CC
= 1.65 V to 1.95 V
V
IL
V
I
V
O
Low-level input voltage
Input voltage
Output voltage
V
CC
= 1.65 V
I
OH
High-level output current
V
CC
= 2.3 V
V
CC
= 2.7 V
V
CC
= 3 V
V
CC
= 1.65 V
I
OL
Low-level output current
V
CC
= 2.3 V
V
CC
= 2.7 V
V
CC
= 3 V
Δt/Δv
(1)
Input transition rise or fall rate
V
CC
= 2.3 V to 2.7 V
V
CC
= 2.7 V to 3.6 V
0
0
1.65
1.5
0.65 × V
CC
1.7
2
0.35 × V
CC
0.7
0.8
5.5
V
CC
–4
–8
–12
–24
4
8
12
24
10
0
0
MAX
3.6
–40°C TO 85°C
MIN
1.65
1.5
0.65 × V
CC
1.7
2
0.35 × V
CC
0.7
0.8
5.5
V
CC
–4
–8
–12
–24
4
8
12
24
10
ns/V
mA
mA
V
V
V
V
MAX
3.6
UNIT
V
All unused inputs of the device must be held at V
CC
or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs,
literature number SCBA004.
4
Product Folder Link(s):
Copyright © 1993–2010, Texas Instruments Incorporated