SN74AHCT1G08
SINGLE 2 INPUT POSITIVE AND GATE
SCLS315O − MARCH 1996 − REVISED JUNE 2005
switching characteristics over recommended operating free-air temperature range,
V
CC
= 5 V
±
0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
tPLH
tPHL
tPLH
tPHL
FROM
(INPUT)
A or B
A or B
TO
(OUTPUT)
Y
Y
LOAD
CAPACITANCE
CL = 15 pF
CL = 50 pF
TA = 25°C
MIN
TYP
MAX
5
5
5.5
5.5
6.2
6.2
7.9
7.9
MIN
1
1
1
1
MAX
7.1
7.1
9
9
ns
ns
UNIT
operating characteristics, V
CC
= 5 V, T
A
= 25°C
PARAMETER
Cpd
Power dissipation capacitance
TEST CONDITIONS
No load,
f = 1 MHz
TYP
18
UNIT
pF
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265
3