PCA9555  
REMOTE 16-BIT I2C AND SMBus I/O EXPANDER  
WITH INTERRUPT OUTPUT AND CONFIGURATION REGISTERS  
www.ti.com  
SCPS131DAUGUST 2005REVISED OCTOBER 2006  
Reads  
The bus master first must send the PCA9555 address with the least-significant bit set to a logic 0 (see Figure 4  
for device address). The command byte is sent after the address and determines which register is accessed.  
After a restart, the device address is sent again, but this time, the least-significant bit is set to a logic 1. Data  
from the register defined by the command byte then is sent by the PCA9555 (see Figure 8 through Figure 10).  
After a restart, the value of the register defined by the command byte matches the register being accessed when  
the restart occurred. For example, if the command byte references Input Port 1 before the restart, and the restart  
occurs when Input Port 0 is being read, the stored command byte changes to reference Input Port 0. The  
original command byte is forgotten. If a subsequent restart occurs, Input Port 0 is read first. Data is clocked into  
the register on the rising edge of the ACK clock pulse. After the first byte is read, additional bytes may be read,  
but the data now reflect the information in the other register in the pair. For example, if Input Port 1 is read, the  
next byte read is Input Port 0.  
Data is clocked into the register on the rising edge of the ACK clock pulse. There is no limitation on the number  
of data bytes received in one read transmission, but when the final byte is received, the bus master must not  
acknowledge the data.  
Data From Lower  
or Upper Byte  
Slave Address  
Slave Address  
of Register  
Acknowledge  
From Slave  
Acknowledge  
From Slave  
Acknowledge  
From Slave  
Acknowledge  
From Master  
Data  
Command Byte  
S
0
1
0
0
A2 A1 A0  
0
A
A
S
0
1
0
0
A2 A1 A0  
1
A
MSB  
LSB A  
First Byte  
R/W  
R/W  
At this moment, master transmitter  
becomes master receiver, and  
slave-receiver becomes  
slave-transmitter.  
Data From Upper  
or Lower Byte  
of Register  
No Acknowledge  
From Master  
MSB  
LSB NA  
P
Data  
Last Byte  
Figure 8. Read From Register  
1
2
3
4
5
6
7
8
9
SCL  
SDA  
I0.x  
I1.x  
I0.x  
I1.x  
3
S
0
1
0
0
A2 A1 A0  
1
A
7
6
5
4
3
2
1
0
A
7
6
5
4
3
2
1
0
A
7
6
5
4
3
2
1
0
A
7
6
5
4
2
1
0
1
P
Acknowledge  
From Slave  
Acknowledge  
From Master  
Acknowledge  
From Master  
Acknowledge  
From Master  
R/W  
No Acknowledge  
From Master  
Read From Port 0  
Data Into Port 0  
Read From Port 1  
Data Into Port 1  
INT  
t
iv  
t
ir  
A. Transfer of data can be stopped at any time by a Stop condition. When this occurs, data present at the latest  
acknowledge phase is valid (output mode). It is assumed that the command byte previously has been set to 00 (read  
Input Port register).  
B. This figure eliminates the command byte transfer, a restart, and slave address call between the initial slave address  
call and actual data transfer from the P port (see Figure 8 for these details).  
Figure 9. Read Input Port Register, Scenario 1  
11  
Submit Documentation Feedback