SLFS022H – SEPTEMBER 1973 – REVISED JUNE 2010
www.ti.com
Operating Characteristics
V
CC
= 5 V to 15 V, T
A
= 25°C (unless otherwise noted)
PARAMETER
Each timer, monostable
(3)
Each timer, astable
Each timer, astable
(5)
TEST
CONDITIONS
(1)
MIN
T
A
= 25°C
T
A
= MIN to MAX
T
A
= 25°C
C
L
= 15 pF,
T
A
= 25°C
C
L
= 15 pF,
T
A
= 25°C
SE555
TYP
0.5
1.5
30
90
0.05
0.15
100
100
200
(4)
200
(4)
100
(4)
0.2
(4)
NA555
NE555
SA555
MAX
1.5
(4)
MIN
TYP
1
2.25
50
150
0.1
0.3
100
100
300
300
0.5
MAX
3
UNIT
Initial error of timing
interval
(2)
Temperature coefficient of
timing interval
%
ppm/
°C
%/V
ns
ns
Each timer, monostable
(3)
(5)
(3)
Supply-voltage sensitivity of Each timer, monostable
timing interval
Each timer, astable
(5)
Output-pulse rise time
Output-pulse fall time
(1)
(2)
(3)
(4)
(5)
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
Timing interval error is defined as the difference between the measured value and the average value of a random sample from each
process run.
Values specified are for a device in a monostable circuit similar to
with the following component values: R
A
= 2 kΩ to 100 kΩ,
C = 0.1
mF.
On products compliant to MIL-PRF-38535, this parameter is not production tested.
Values specified are for a device in an astable circuit similar to
with the following component values: R
A
= 1 kΩ to 100 kΩ,
C = 0.1
mF.
6
Copyright © 1973–2010, Texas Instruments Incorporated
Product Folder Link(s):