ꢀ ꢁꢂꢃ ꢄ ꢅ ꢆ ꢇ ꢄ ꢆ ꢈ ꢀ ꢁꢂꢃ ꢄ ꢅ ꢆ ꢇ ꢃ ꢆ ꢈ ꢀ ꢁꢂꢃ ꢄꢅ ꢆꢇꢃ ꢆꢇ
ꢀ ꢉꢊꢋ ꢌ ꢁꢉ ꢍ ꢎꢏꢐ ꢀ ꢉꢑꢒꢓ ꢑꢓ ꢎꢔ ꢒꢓ ꢐꢐ ꢋꢒ
SLAS272F − JULY 2000 − REVISED JUNE 2004
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted) (continued)
Flash Memory
TEST
CONDITIONS
PARAMETER
V
CC
MIN NOM
MAX
UNIT
V
CC(PGM/
ERASE)
Program and Erase supply voltage
Flash Timing Generator frequency
2.7
3.6
V
f
I
I
t
t
257
476
5
kHz
mA
FTG
Supply current from DV
Supply current from DV
during program
during erase
2.7 V/ 3.6 V
2.7 V/ 3.6 V
2.7 V/ 3.6 V
2.7 V/ 3.6 V
3
PGM
CC
3
7
mA
ERASE
CPT
CC
Cumulative program time
see Note 1
see Note 2
4
ms
Cumulative mass erase time
Program/Erase endurance
Data retention duration
200
ms
CMErase
4
5
10
10
100
cycles
years
t
T = 25°C
J
Retention
t
t
t
t
t
t
Word or byte program time
35
30
Word
st
Block program time for 1 byte or word
Block, 0
Block program time for each additional byte or word
Block program end-sequence wait time
Mass erase time
21
Block, 1-63
Block, End
Mass Erase
Seg Erase
see Note 3
t
FTG
6
5297
4819
Segment erase time
NOTES: 1. The cumulative program time must not be exceeded when writing to a 64-byte flash block. This parameter applies to all programming
methods: individual word/byte write and block write modes.
2. The mass erase duration generated by the flash timing generator is at least 11.1ms ( = 5297x1/f
,max = 5297x1/476kHz). To
FTG
achieve the required cumulative mass erase time the Flash Controller’s mass erase operation can be repeated until this time is met.
(A worst case minimum of 19 cycles are required).
3. These values are hardwired into the Flash Controller’s state machine (t
FTG
= 1/f
FTG
).
JTAG Interface
TEST
CONDITIONS
PARAMETER
V
CC
MIN NOM
MAX
UNIT
2.2 V
3 V
0
0
5
10
90
MHz
MHz
kΩ
f
TCK input frequency
see Note 1
TCK
R
Internal pull-up resistance on TMS, TCK, TDI/TCLK see Note 2
may be restricted to meet the timing requirements of the module selected.
2.2 V/ 3 V
25
60
Internal
NOTES: 1. f
TCK
2. TMS, TDI/TCLK, and TCK pull-up resistors are implemented in all versions.
JTAG Fuse (see Note 1)
TEST
CONDITIONS
PARAMETER
V
CC
MIN NOM
MAX
UNIT
V
V
Supply voltage during fuse-blow condition
Voltage level on TDI/TCLK for fuse-blow: F versions
Supply current into TDI/TCLK during fuse blow
Time to blow fuse
T
A
= 25°C
2.5
6
V
V
CC(FB)
7
100
1
FB
I
t
mA
ms
FB
FB
NOTES: 1. Once the fuse is blown, no further access to the MSP430 JTAG/Test and emulation features is possible. The JTAG block is switched
to bypass mode.
39
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265