ꢀ ꢁꢂ ꢃꢄꢅꢆ ꢇ ꢈ ꢉ
ꢊꢋ ꢊꢌꢅ ꢍ ꢎꢆ ꢏꢐ ꢍ ꢑꢒ ꢐꢓ ꢄꢔ ꢎꢐ ꢀ ꢎꢐ ꢕꢕ ꢔꢒ
ꢖꢗ ꢆ ꢘ ꢊ ꢌꢀꢆꢍꢆ ꢔ ꢙꢐꢆ ꢓ ꢐꢆꢀ
SCBS133F − MAY 1992 − REVISED OCTOBER 2003
FUNCTION TABLE
(each buffer)
INPUTS
OUTPUT
Y
OE
A
H
L
L
L
H
L
H
X
Z
logic diagram (positive logic)
1
1OE
1A
2
4
5
3
6
1Y
2Y
2OE
2A
10
9
3OE
3A
8
3Y
4Y
13
12
4OE
4A
11
†
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 4.6 V
CC
Input voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
I
Voltage range applied to any output in the high state or power-off state, V (see Note 1) . . . . −0.5 V to 7 V
O
Current into any output in the low state, I
Current into any output in the high state, I (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 mA
O
O
Input clamp current, I (V < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −50 mA
IK
I
Output clamp current, I
(V < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −50 mA
OK
O
Package thermal impedance, θ (see Note 3): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86°C/W
JA
DB package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96°C/W
NS package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76°C/W
PW package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113°C/W
Storage temperature range, T
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
stg
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2. This current flows only when the output is in the high state and V > V
.
CC
O
3. The package thermal impedance is calculated in accordance with JESD 51-7.
2