 浏览型号LMC6482AIM-NOPB的Datasheet PDF文件第18页浏览型号LMC6482AIM-NOPB的Datasheet PDF文件第19页浏览型号LMC6482AIM-NOPB的Datasheet PDF文件第20页浏览型号LMC6482AIM-NOPB的Datasheet PDF文件第21页浏览型号LMC6482AIM-NOPB的Datasheet PDF文件第23页浏览型号LMC6482AIM-NOPB的Datasheet PDF文件第24页浏览型号LMC6482AIM-NOPB的Datasheet PDF文件第25页浏览型号LMC6482AIM-NOPB的Datasheet PDF文件第26页  
LMC6482  
SNOS674D NOVEMBER 1997REVISED MARCH 2013  
www.ti.com  
V+  
R4  
R3  
5V  
500 kW  
1 kW  
V
IN  
-
1
LMC6482  
-5V  
V
OUT  
2
1 MW  
+
499W  
500 kW  
V
OUT  
R4  
R3  
= -  
V-  
V
IN  
V-  
Figure 69. Inverting Configuration Offset Voltage Adjustment  
Figure 70. Non-Inverting Configuration Offset Voltage Adjustment  
UPGRADING APPLICATIONS  
The LMC6484 quads and LMC6482 duals have industry standard pin outs to retrofit existing applications.  
System performance can be greatly increased by the LMC6482's features. The key benefit of designing in the  
LMC6482 is increased linear signal range. Most op-amps have limited input common mode ranges. Signals that  
exceed this range generate a non-linear output response that persists long after the input signal returns to the  
common mode range.  
Linear signal range is vital in applications such as filters where signal peaking can exceed input common mode  
ranges resulting in output phase inversion or severe distortion.  
DATA ACQUISITION SYSTEMS  
Low power, single supply data acquisition system solutions are provided by buffering the ADC12038 with the  
LMC6482 (Figure 71). Capable of using the full supply range, the LMC6482 does not require input signals to be  
scaled down to meet limited common mode voltage ranges. The LMC4282 CMRR of 82dB maintains integral  
linearity of a 12-bit data acquisition system to ±0.325 LSB. Other rail-to-rail input amplifiers with only 50dB of  
CMRR will degrade the accuracy of the data acquisition system to only 8 bits.  
22  
Submit Documentation Feedback  
Copyright © 1997–2013, Texas Instruments Incorporated  
Product Folder Links: LMC6482  
 复制成功!