欢迎访问ic37.com |
会员登录 免费注册
发布采购

LM4041CIM3X-1.2 参数 Datasheet PDF下载

LM4041CIM3X-1.2图片预览
型号: LM4041CIM3X-1.2
PDF下载: 下载PDF文件 查看货源
内容描述: LM4041 -N / LM4041 -N -Q1精密微功耗并联型电压基准 [LM4041-N/LM4041-N-Q1 Precision Micropower Shunt Voltage Reference]
分类和应用: 电源电路参考电压源光电二极管
文件页数/大小: 34 页 / 1329 K
品牌: TI [ TEXAS INSTRUMENTS ]
 浏览型号LM4041CIM3X-1.2的Datasheet PDF文件第1页浏览型号LM4041CIM3X-1.2的Datasheet PDF文件第2页浏览型号LM4041CIM3X-1.2的Datasheet PDF文件第4页浏览型号LM4041CIM3X-1.2的Datasheet PDF文件第5页浏览型号LM4041CIM3X-1.2的Datasheet PDF文件第6页浏览型号LM4041CIM3X-1.2的Datasheet PDF文件第7页浏览型号LM4041CIM3X-1.2的Datasheet PDF文件第8页浏览型号LM4041CIM3X-1.2的Datasheet PDF文件第9页  
LM4041-N, LM4041-N-Q1  
www.ti.com  
SNOS641F OCTOBER 1999REVISED JULY 2013  
Operating Ratings(1)(2)  
Temperature Range  
(Tmin TA Tmax  
)
Industrial Temperature Range  
Extended Temperature Range  
Reverse Current  
40°C TA +85°C  
40°C TA +125°C  
60 μA to 12 mA  
LM4041-N 1.2, LM4041-N-Q1 1.2  
LM4041-N ADJ, LM4041-N-Q1 ADJ  
LM4041-N ADJ, LM4041-N-Q1 ADJ  
60 μA to 12 mA  
Output Voltage Range  
1.24V to 10V  
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for  
which the device is functional, but do not ensure specific performance limits. For ensured specifications and test conditions, see the  
Electrical Characteristics. The ensured specifications apply only for the test conditions listed. Some performance characteristics may  
degrade when the device is not operated under the listed test conditions.  
(2) The maximum power dissipation must be derated at elevated temperatures and is dictated by TJmax (maximum junction temperature),  
θJA (junction to ambient thermal resistance), and TA (ambient temperature). The maximum allowable power dissipation at any  
temperature is PDmax = (TJmax TA)/θJA or the number given in the Absolute Maximum Ratings, whichever is lower. For the LM4041-N,  
TJmax = 125°C, and the typical thermal resistance (θJA), when board mounted, is 326°C/W for the SOT-23 package, 415°C/W for the  
SC70 package and 180°C/W with 0.4lead length and 170°C/W with 0.125lead length for the TO-92 package.  
LM4041-N/LM4041-N-Q1 1.2 Electrical Characteristics (Industrial Temperature Range)  
Boldface limits apply for TA = TJ = TMIN to TMAX; all other limits TA = TJ = 25°C. The grades A and B designate initial  
Reverse Breakdown Voltage tolerances of ±0.1% and ±0.2%, respectively.  
Symbol  
Parameter  
Conditions  
Typical(1)  
LM4041AIM3  
LM4041QAIM3  
LM4041AIM3  
LM4041AIZ  
Limits(2)  
LM4041BIM3  
LM4041QBIM3  
LM4041BIZ  
LM4041BIM7  
Limits(2)  
Units  
(Limit)  
VR  
Reverse Breakdown Voltage  
IR = 100 μA  
1.225  
45  
V
Reverse Breakdown Voltage  
Tolerance(3)  
IR = 100 μA  
±1.2  
±2.4  
mV (max)  
mV (max)  
μA  
±9.2  
±10.4  
IRMIN  
Minimum Operating Current  
60  
60  
μA (max)  
μA (max)  
ppm/°C  
65  
65  
ΔVR/ΔT Average Reverse Breakdown  
Voltage Temperature  
IR= 10 mA  
IR = 1 mA  
IR = 100 μA  
±20  
±15  
±15  
±100  
±100  
ppm/°C (max)  
ppm/°C  
Coefficient(3)  
(1) Typicals are at TJ = 25°C and represent most likely parametric norm.  
(2) Limits are 100% production tested at 25°C. Limits over temperature are ensured through correlation using Statistical Quality Control  
(SQC) methods. The limits are used to calculate AOQL.  
(3) The boldface (over-temperature) limit for Reverse Breakdown Voltage Tolerance is defined as the room temperature Reverse  
Breakdown Voltage Tolerance ±[(ΔVRΔT)(max ΔT)(VR)]. Where, ΔVR/ΔT is the VR temperature coefficient, maxΔT is the maximum  
difference in temperature from the reference point of 25 °C to T MAX or TMIN, and VR is the reverse breakdown voltage. The total over-  
temperature tolerance for the different grades in the industrial temperature range where maxΔT=65°C is shown below:  
A-grade: ±0.75% = ±0.1% ±100 ppm/°C × 65°C  
B-grade: ±0.85% = ±0.2% ±100 ppm/°C × 65°C  
C-grade: ±1.15% = ±0.5% ±100 ppm/°C × 65°C  
D-grade: ±1.98% = ±1.0% ±150 ppm/°C × 65°C  
E-grade: ±2.98% = ±2.0% ±150 ppm/°C × 65°C  
The total over-temperature tolerance for the different grades in the extended temperature range where max ΔT = 100 °C is shown  
below:  
B-grade: ±1.2% = ±0.2% ±100 ppm/°C × 100°C  
C-grade: ±1.5% = ±0.5% ±100 ppm/°C × 100°C  
D-grade: ±2.5% = ±1.0% ±150 ppm/°C × 100°C  
E-grade: ±4.5% = ±2.0% ±150 ppm/°C × 100°C  
Therefore, as an example, the A-grade LM4041-N 1.2 has an over-temperature Reverse Breakdown Voltage tolerance of ±1.2V × 0.75%  
= ±9.2 mV.  
Copyright © 1999–2013, Texas Instruments Incorporated  
Submit Documentation Feedback  
3
Product Folder Links: LM4041-N, LM4041-N-Q1  
 复制成功!