LM158, LM158A, LM258, LM258A
LM358, LM358A, LM2904, LM2904V
DUAL OPERATIONAL AMPLIFIERS
SLOS068R − JUNE 1976 − REVISED JULY 2010
electrical characteristics at specified free-air temperature, VCC = 5 V (unless otherwise noted)
LM2904
†
‡
PARAMETER
TEST CONDITIONS
T
A
UNIT
§
MIN
TYP
MAX
7
25°C
Full range
25°C
3
1
Non-A devices
A-suffix devices
V
V
V
= 5 V to MAX,
CC
10
2
= V
,
V
IO
Input offset voltage
mV
IC
O
ICR(min)
= 1.4 V
Full range
4
Average temperature coefficient
of input offset voltage
aVIO
Full range
7
2
µV/°C
25°C
Full range
25°C
50
300
50
Non-V device
V-suffix device
I
IO
Input offset current
V
= 1.4 V
= 1.4 V
nA
O
2
Full range
150
Average temperature coefficient
of input offset current
aIIO
Full range
10
pA/°C
25°C
−20 −250
−500
I
IB
Input bias current
V
V
nA
O
Full range
0 to
25°C
V
V
− 1.5
CC
Common-mode input voltage
range
V
ICR
= 5 V to MAX
V
V
CC
0 to
Full range
− 2
CC
R
≥ 10 kΩ
25°C
Full range
Full range
Full range
Full range
Full range
25°C
V
CC
− 1.5
L
R = 2 kΩ
L
22
V
CC
= MAX,
Non-V device
R
≥ 10 kΩ
23
26
27
24
28
V
V
High-level output voltage
Low-level output voltage
L
OH
R = 2 kΩ
L
V
CC
= MAX,
V-suffix device
R
≥ 10 kΩ
L
R
≤ 10 kΩ
5
20
mV
OL
L
25
15
50
65
100
Large-signal differential
voltage amplification
V
CC
= 15 V, V = 1 V to 11 V,
O
A
VD
V/mV
R
≥ 2 kΩ
L
Full range
25°C
Non-V device
80
80
V
V
= 5 V to MAX,
CC
CMRR
Common-mode rejection ratio
Supply-voltage rejection ratio
dB
dB
= V
IC
ICR(min)
V-suffix device
25°C
k
V
CC
= 5 V to MAX
25°C
65
100
SVR
(∆V /∆V
)
IO
DD
V
/V
O1 O2
Crosstalk attenuation
f = 1 kHz to 20 kHz
25°C
25°C
120
−30
dB
mA
mA
−20
−10
V
V
= 15 V,
= 1 V, V = 0
CC
Source
Sink
ID
O
Full range
V
V
V
= 15 V,
= −1 V,
= 15 V
25°C
10
5
20
mA
mA
CC
I
O
Output current
ID
O
Full range
Non-V device
V-suffix device
25°C
25°C
30
40
40
0.7
1
V
V
= −1 V,
= 200 mV
ID
O
µA
mA
mA
12
I
I
Short-circuit output current
V
V
V
at 5 V, GND at −5 V, V = 0
25°C
60
1.2
2
OS
CC
O
= 2.5 V, No load
Full range
Full range
O
Supply current (two amplifiers)
CC
= MAX, V = 0.5 V, No load
CC
O
†
All characteristics are measured under open-loop conditions, with zero common-mode input voltage, unless otherwise specified. MAX V for
CC
testing purposes is 26 V for the LM2904, 32 V for the LM2904V, and 30 V for others.
Full range is −55°C to 125°C for LM158, −25°C to 85°C for LM258, 0°C to 70°C for LM358, and −40°C to 125°C for LM2904.
‡
§
All typical values are at T = 25°C.
A
7