SNOS412L – MAY 2004 – REVISED JULY 2012
LM1117I ELECTRICAL CHARACTERISTICS
Typicals and limits appearing in normal type apply for T
J
= 25°C. Limits appearing in
Boldface
type apply over the entire
junction temperature range for operation,
−40°C
to 125°C.
Symbol
V
REF
Parameter
Reference Voltage
Conditions
LM1117I-ADJ
I
OUT
= 10mA, V
IN
-V
OUT
= 2V, T
J
= 25°C
10mA
≤
I
OUT
≤
800mA, 1.4V
≤
V
IN
-V
OUT
≤
10V
LM1117I-3.3
I
OUT
= 10mA, V
IN
= 5V, T
J
= 25°C
0
≤
I
OUT
≤
800mA, 4.75V
≤
V
IN
≤
10V
LM1117I-5.0
I
OUT
= 10mA, V
IN
= 7V, T
J
= 25°C
0
≤
I
OUT
≤
800mA, 6.5V
≤
V
IN
≤
12V
ΔV
OUT
Line Regulation
(3)
LM1117I-ADJ
I
OUT
= 10mA, 1.5V
≤
V
IN
-V
OUT
≤
13.75V
LM1117I-3.3
I
OUT
= 0mA, 4.75V
≤
V
IN
≤
15V
LM1117I-5.0
I
OUT
= 0mA, 6.5V
≤
V
IN
≤
15V
ΔV
OUT
Load Regulation
(3)
Min
(1)
1.238
1.200
Typ
(2)
1.250
1.250
Max
(1)
1.262
1.290
Units
V
V
V
OUT
Output Voltage
3.267
3.168
4.950
4.800
3.300
3.300
5.000
5.000
0.035
1
1
0.2
1
1
1.10
1.15
1.20
3.333
3.432
5.050
5.200
0.3
10
15
0.5
15
20
1.30
1.35
1.40
1500
5
15
15
0.1
V
V
V
V
%
mV
mV
%
mV
mV
V
V
V
mA
mA
mA
mA
%/W
dB
LM1117I-ADJ
V
IN
-V
OUT
= 3V, 10
≤
I
OUT
≤
800mA
LM1117I-3.3
V
IN
= 4.75V, 0
≤
I
OUT
≤
800mA
LM1117I-5.0
V
IN
= 6.5V, 0
≤
I
OUT
≤
800mA
V
IN
-V
OUT
Dropout Voltage
(4)
I
OUT
= 100mA
I
OUT
= 500mA
I
OUT
= 800mA
I
LIMIT
Current Limit
Minimum Load
Current
(5)
Quiescent Current
V
IN
-V
OUT
= 5V, T
J
= 25°C
LM1117I-ADJ
V
IN
= 15V
LM1117I-3.3
V
IN
≤
15V
LM1117I-5.0
V
IN
≤
15V
800
1200
1.7
5
5
0.01
Thermal Regulation
Ripple Regulation
Adjust Pin Current
Adjust Pin Current
Change
Temperature Stability
Long Term Stability
RMS Output Noise
Thermal Resistance
Junction-to-Case
T
A
= 25°C, 30ms Pulse
f
RIPPLE
=1 20Hz, V
IN
-V
OUT
= 3V V
RIPPLE
=
1V
PP
10
≤
I
OUT
≤
800mA,
1.4V
≤
V
IN
-V
OUT
≤
10V
T
A
= 125°C, 1000Hrs
(% of V
OUT
), 10Hz
≤
f
≤10kHz
3-Lead SOT-223
3-Lead TO-252
60
75
60
0.2
0.5
0.3
0.003
15.0
10
120
10
μA
μA
%
%
%
°C/W
°C/W
(1)
(2)
(3)
(4)
(5)
6
All limits are guaranteed by testing or statistical analysis.
Typical Values represent the most likely parametric norm.
Load and line regulation are measured at constant junction room temperature.
The dropout voltage is the input/output differential at which the circuit ceases to regulate against further reduction in input voltage. It is
measured when the output voltage has dropped 100mV from the nominal value obtained at V
IN
= V
OUT
+1.5V.
The minimum output current required to maintain regulation.
Product Folder Links:
Copyright © 2004–2012, Texas Instruments Incorporated