LM1117-N
SNOS412L –MAY 2004–REVISED JULY 2012
www.ti.com
LM1117 ELECTRICAL CHARACTERISTICS
Typicals and limits appearing in normal type apply for TJ = 25°C. Limits appearing in Boldface type apply over the entire
junction temperature range for operation, 0°C to 125°C.
Symbol
Parameter
Conditions
Min(1)
Typ(2)
Max(1)
Units
VREF
Reference Voltage
LM1117-ADJ
IOUT = 10mA, VIN-VOUT = 2V, TJ = 25°C
10mA ≤ IOUT ≤ 800mA, 1.4V ≤ VIN-VOUT
10V
1.238
1.225
1.250
1.250
1.262
1.270
V
V
≤
VOUT
Output Voltage
LM1117-1.8
IOUT = 10mA, VIN = 3.8V, TJ = 25°C
0 ≤ IOUT ≤ 800mA, 3.2V ≤ VIN ≤ 10V
1.782
1.746
1.800
1.800
1.818
1.854
V
V
LM1117-2.5
IOUT = 10mA, VIN = 4.5V, TJ = 25°C
0 ≤ IOUT ≤ 800mA, 3.9V ≤ VIN ≤ 10V
2.475
2.450
2.500
2.500
2.525
2.550
V
V
LM1117-2.85
IOUT = 10mA, VIN = 4.85V, TJ = 25°C
0 ≤ IOUT ≤ 800mA, 4.25V ≤ VIN ≤ 10V
0 ≤ IOUT ≤ 500mA, VIN = 4.10V
2.820
2.790
2.790
2.850
2.850
2.850
2.880
2.910
2.910
V
V
V
LM1117-3.3
IOUT = 10mA, VIN = 5V TJ = 25°C
0 ≤ IOUT ≤ 800mA, 4.75V≤ VIN ≤ 10V
3.267
3.235
3.300
3.300
3.333
3.365
V
V
LM1117-5.0
IOUT = 10mA, VIN = 7V, TJ = 25°C
0 ≤ IOUT ≤ 800mA, 6.5V ≤ VIN ≤ 12V
4.950
4.900
5.000
5.000
5.050
5.100
V
V
ΔVOUT
Line Regulation(3)
LM1117-ADJ
IOUT = 10mA, 1.5V ≤ VIN-VOUT ≤ 13.75V
0.035
1
0.2
6
%
LM1117-1.8
mV
IOUT = 0mA, 3.2V ≤ VIN ≤ 10V
LM1117-2.5
1
6
mV
IOUT = 0mA, 3.9V ≤ VIN ≤ 10V
LM1117-2.85
IOUT = 0mA, 4.25V ≤ VIN ≤ 10V
1
1
1
6
6
mV
mV
mV
LM1117-3.3
IOUT = 0mA, 4.75V ≤ VIN ≤ 15V
LM1117-5.0
IOUT = 0mA, 6.5V ≤ VIN ≤ 15V
10
ΔVOUT
Load Regulation(3)
LM1117-ADJ
VIN-VOUT = 3V, 10 ≤ IOUT ≤ 800mA
0.2
1
0.4
10
%
LM1117-1.8
mV
VIN = 3.2V, 0 ≤ IOUT ≤ 800mA
LM1117-2.5
1
10
mV
VIN = 3.9V, 0 ≤ IOUT ≤ 800mA
LM1117-2.85
VIN = 4.25V, 0 ≤ IOUT ≤ 800mA
1
1
10
10
mV
mV
LM1117-3.3
VIN = 4.75V, 0 ≤ IOUT ≤ 800mA
LM1117-5.0
VIN = 6.5V, 0 ≤ IOUT ≤ 800mA
1
15
mV
V
VIN-V
Dropout Voltage(4)
Current Limit
IOUT = 100mA
1.10
1.15
1.20
1200
1.20
1.25
1.30
1500
OUT
IOUT = 500mA
V
IOUT = 800mA
V
ILIMIT
VIN-VOUT = 5V, TJ = 25°C
800
mA
Minimum Load
Current(5)
LM1117-ADJ
VIN = 15V
1.7
5
mA
(1) All limits are guaranteed by testing or statistical analysis.
(2) Typical Values represent the most likely parametric norm.
(3) Load and line regulation are measured at constant junction room temperature.
(4) The dropout voltage is the input/output differential at which the circuit ceases to regulate against further reduction in input voltage. It is
measured when the output voltage has dropped 100mV from the nominal value obtained at VIN = VOUT +1.5V.
(5) The minimum output current required to maintain regulation.