 浏览型号DS90LV032ATM/NOPB的Datasheet PDF文件第1页浏览型号DS90LV032ATM/NOPB的Datasheet PDF文件第2页浏览型号DS90LV032ATM/NOPB的Datasheet PDF文件第3页浏览型号DS90LV032ATM/NOPB的Datasheet PDF文件第5页浏览型号DS90LV032ATM/NOPB的Datasheet PDF文件第6页浏览型号DS90LV032ATM/NOPB的Datasheet PDF文件第7页浏览型号DS90LV032ATM/NOPB的Datasheet PDF文件第8页浏览型号DS90LV032ATM/NOPB的Datasheet PDF文件第9页  
SNLS011C – JULY 1999 – REVISED APRIL 2013
Electrical Characteristics
Over Supply Voltage and Operating Temperature ranges, unless otherwise specified.
Symbol
V
TH
V
TL
VCMR
I
IN
Parameter
Differential Input High Threshold
Differential Input Low Threshold
Common-Mode Voltage Range
Input Current
VID = 200 mV peak to peak
V
IN
= +2.8V
V
IN
= 0V
V
IN
= +3.6V
V
OH
Output High Voltage
V
CC
= 0V
R
OUT
I
OH
=
−0.4
mA, V
ID
= +200 mV
I
OH
=
−0.4
mA, Input terminated
I
OH
=
−0.4
mA, Input shorted
V
OL
I
OS
I
OZ
V
IH
V
IL
I
I
V
CL
I
CC
I
CCZ
(1)
(2)
(3)
Output Low Voltage
Output Short Circuit Current
Output TRI-STATE Current
Input High Voltage
Input Low Voltage
Input Current
Input Clamp Voltage
No Load Supply Current
Receivers Enabled
No Load Supply Current
Receivers Disabled
V
IN
= 0V or V
CC
, Other Input = V
CC
or GND
I
CL
=
−18
mA
EN, EN* = V
CC
or GND, Inputs Open
EN, EN* = 2.4V or 0.5V, Inputs Open
EN = GND, EN* = V
CC
, Inputs Open
V
CC
I
OL
= 2 mA, V
ID
=
−200
mV
Enabled, V
OUT
= 0V
(4)
(3)
(1)
Conditions
V
CM
= +1.2V
(2)
Pin
R
IN+
,
R
IN−
Min
−100
0.1
−10
−10
-20
2.7
2.7
2.7
−15
−10
Typ
+20
−20
Max
+100
2.3
Units
mV
mV
V
μA
μA
μA
V
V
V
V
CC
= 3.6V or 0V
±1
±1
3.0
3.0
3.0
0.1
−48
±1
+10
+10
+20
0.25
−120
+10
V
CC
0.8
V
mA
μA
V
V
μA
V
mA
mA
mA
Disabled, V
OUT
= 0V or V
CC
EN,
EN*
2.0
GND
−10
−1.5
±1
−0.8
10
10
3
+10
15
15
5
(4)
Current into device pins is defined as positive. Current out of device pins is defined as negative. All voltages are referenced to ground
unless otherwise specified.
V
CC
is always higher than R
IN+
and R
IN−
voltage. R
IN−
and R
IN+
are allowed to have a voltage range
−0.2V
to V
CC
VID/2. However, to
be compliant with AC specifications, the common voltage range is 0.1V to 2.3V
The VCMR range is reduced for larger VID. Example: if VID = 400mV, the VCMR is 0.2V to 2.2V. The fail-safe condition with inputs
shorted is valid over a common-mode range of 0V to 2.3V. A VID up to V
CC
0V may be applied to the R
IN+
/ R
IN−
inputs with the
Common-Mode voltage set to V
CC
/2. Propagation delay and Differential Pulse skew decrease when VID is increased from 200mV to
400mV. Skew specifications apply for 200mV
VID
800mV over the common-mode range .
Output short circuit current (I
OS
) is specified as magnitude only, minus sign indicates direction only. Only one output should be shorted
at a time, do not exceed maximum junction temperature specification.
4
Product Folder Links:
Copyright © 1999–2013, Texas Instruments Incorporated