SNLS354D – MAY 1998 – REVISED APRIL 2013
Electrical Characteristics
(continued)
(Unless otherwise noted, minimum and maximum limits apply over recommended temperature and power supply voltage
ranges. Typical values are for T
A
= 25°C, V
CC
= 5V and V
IC
= 0V.)
Symbol
I
OZ
I
OS
I
IL
I
IH
V
IC
I
CC
(3)
Parameter
Output TRI-STATE Leakage Current
Output Short-Circuit Current
Input Current—Low Logic State
(TRI-STATE Control)
Input Current—High Logic State
(TRI-STATE Control)
Input Clamp Diode Voltage
(TRI-STATE Control)
Power Supply Current
Only one output at a time should be shorted.
Conditions
V
I(D)
= 3V, V
IL
= 0.8V, V
OL
= 0.5V
V
I(D)
=
−3V,
V
IL
= 0.8V, V
OH
= 2.7V
V
I(D)
= 3V, V
IH
TRI-STATE = 2V,
V
O
= 0V,
(3)
Min
Typ
Max
−40
40
Units
μA
μA
mA
−15
−100
V
IL
= 0.5V
V
IH
= 2.7V
V
IH
= 5.25V
I
IN
=
−10
mA
All Inputs V
IL
= 0V
−100
20
100
−1.5
85
μA
μA
μA
V
mA
Switching Characteristics
(Unless otherwise noted, V
CC
= 5V and T
A
= 25°C.)
Symbol
t
PHL(D)
t
PLH(D)
t
PLZ
t
PHZ
t
PZH
t
PZL
Parameter
Propagation Delay Time—Differential Inputs to Output
Output High to Low
Output Low to High
TRI-STATE Control to Output
Output Low to TRI-STATE
Output High to TRI-STATE
Output TRI-STATE to High
Output TRI-STATE to Low
Min
Typ
19
19
23
25
18
20
Max
35
30
35
35
30
30
Units
ns
ns
ns
ns
ns
ns
AC TEST CIRCUIT AND SWITCHING TIME WAVEFORMS
Copyright © 1998–2013, Texas Instruments Incorporated
Product Folder Links:
3