SNLS394J – JANUARY 2000 – REVISED APRIL 2013
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
Absolute Maximum Ratings
(1) (2)
Storage Temperature Range
Operating Temperature Range, T
A
DS2003T
DS2003C
Junction Temperature Range, T
J
Lead Temperature
Soldering, 10 seconds
ESD Ratings
Human Body Model
Machine Model
Package Thermal Dissipation Ratings
NFG0016E Package
θ
J-A
D0016A Package
θ
J-A
Input Voltage
Output Voltage
Emitter-Base Voltage
Continuous Collector Current
Continuous Base Current
(1)
(2)
88°C/W
115°C/W
−0.3V
to 30V
55V
6.0V
500 mA
25 mA
+/-2000V
+/- 200V
265°C
−40°C
to +125°C
−40°C
to +85°C
−40°C
to +150°C
−65°C
to +150°C
“Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be specified. They are not meant to imply
that the devices should be operated at these limits. The
provide conditions for actual device operation.
If Military/Aerospace specified devices are required, please contact the TI Sales Office/Distributors for availability and specifications.
Electrical Characteristics
T
A
= 25°C, unless otherwise specified
Parameter
I
CEX
Output Leakage
Current
(1)
Test Conditions
T
A
= 25°C, V
CE
= 50V (Figure
6)
T
A
= 85°C, V
CE
= 50V (Figure
6)
T
A
= 125°C, V
CE
= 50V (Figure
6)
for DS2003T
I
C
= 350mA, I
B
= 500μA (Figure
8)
(2)
I
C
= 200mA, I
B
= 350μA (Figure
8)
I
C
= 100mA, I
B
= 250μA (Figure
8)
V
I
= 3.85V (Figure
9)
I
C
= 500µA (Figure
T
A
= +25°C
T
A
= +85°C
T
A
= +125C for DS2003T
Min
Typ
Max
20
100
150
Units
μA
V
CE(Sat)
Collector-Emitter
Saturation Voltage
1.25
1.1
0.9
0.93
50
50
25
10
100
100
50
25
1.6
1.3
1.1
1.35
V
I
I(ON)
I
I(OFF)
Input Current
Input Current
(3)
mA
μA
V
I(ON)
Input Voltage
(4)
V
CE
= 2.0V, I
C
= 200mA (Figure
V
CE
= 2.0V, I
C
= 250mA (Figure
V
CE
= 2.0V, I
C
= 300mA (Figure
2.4
2.7
3.0
15
30
1.0
1.0
V
C
I
t
PLH
t
PHL
(1)
(2)
(3)
(4)
2
Input Capacitance
Turn-On Delay
Turn-Off Delay
0.5 V
I
to 0.5 V
O
0.5 V
I
to 0.5 V
O
pF
μs
μs
All limits apply to the complete Darlington series except as specified for a single device type.
Under normal operating conditions these units will sustain 350 mA per output with V
CE (Sat)
= 1.6V at 70°C with a pulse width of 20 ms
and a duty cycle of 30%.
The I
I(OFF)
current limit ensured against partial turn-on of the output.
The V
I(ON)
voltage limit ensures a minimum output sink current per the specified test conditions.
Product Folder Links:
Copyright © 2000–2013, Texas Instruments Incorporated