8.2.21 10BASE-T Normal Link Pulse Timing
T2.21.2
T2.21.1
Normal Link Pulse(s)
Parameter
Description
Notes
Min
Typ Max Units
T2.21.1
T2.21.2
Pulse Width
Pulse Period
100
16
ns
ms
Note: These specifications represent transmit timings.
8.2.22 Auto-Negotiation Fast Link Pulse (FLP) Timing
T2.22.2
T2.22.3
T2.22.1
T2.22.1
Fast Link Pulse(s)
clock
pulse
data
pulse
clock
pulse
T2.22.5
T2.22.4
FLP Burst
FLP Burst
Parameter
T2.22.1
Description
Notes
Min
Typ Max Units
Clock, Data Pulse Width
100
125
ns
T2.22.2
Clock Pulse to Clock Pulse
Period
µs
T2.22.3
Clock Pulse to Data Pulse
Period
Data = 1
62
µs
T2.22.4
T2.22.5
Burst Width
2
ms
ms
FLP Burst to FLP Burst Period
16
Note: These specifications represent transmit timings.
www.national.com
76