8.0 Electrical Specifications (Continued)
8.6.7 10BASE-T Normal Link Pulse Timing
Parameter
Description
Notes
Min
80
8
Typ Max Units
T1
T2
Clock, Data Pulse Width
100
16
130
24
ns
Clock Pulse to Clock Pulse
Period
ms
T2
T1
8.7 Auto-Negotiation Fast Link Pulse (FLP) Timing
8.7.1 Auto-Negotiation Fast Link Pulse (FLP) timing
Parameter
Description
Notes
Min
Typ Max Units
T1
T2
Clock, Data Pulse Width
80
100
125
130
139
ns
Clock Pulse to Clock Pulse
Period
111
µs
T3
Clock Pulse to Data Pulse
Period
Data = 1
55.5
17
69.5
33
µs
T4
T5
T6
Number of Pulses in a Burst
Burst Width
#
2
ms
ms
FLP Burst to FLP Burst Period
8
24
T2
T3
T1
T1
Fast Link Pulse(s)
clock
pulse
data
clock
pulse
pulse
T6
T4
T5
FLP Burst
FLP Burst
Version A
84