CC1000  
1. Absolute Maximum Ratings  
Parameter  
Min.  
-0.3  
-0.3  
Max.  
Units  
V
V
Condition  
Supply voltage, VDD  
5.0  
VDD+0.3,  
max 5.0  
10  
Voltage on any pin  
Input RF level  
dBm  
Storage temperature range  
(TSSOP)  
-50  
150  
°C  
Shelf life (UltraCSP™)  
1
year  
°C  
Room temperature and oxygen  
free cabinet  
Reflow soldering temperature  
(TSSOP)  
Peak reflow soldering temperature  
(UltraCSP™)  
260  
255  
IPC/JEDEC J-STD-020C  
IPC/JEDEC J-STD-020C  
°C  
Under no circumstances the absolute  
maximum ratings given above should be  
violated. Stress exceeding one or more of  
the limiting values may cause permanent  
damage to the device.  
Caution! ESD sensitive device.  
Precaution should be used when handling  
the device in order to prevent permanent  
damage.  
2. Operating Conditions  
Parameter  
Min.  
Typ.  
Max.  
Unit  
Condition / Note  
RF Frequency Range  
300  
-40  
1000  
85  
MHz  
Programmable in steps of 250 Hz  
Operating ambient temperature range  
Supply voltage  
°C  
2.1  
3.0  
3.6  
V
Note: The same supply voltage  
should be used for digital (DVDD)  
and analogue (AVDD) power.  
3. Electrical Specifications  
Tc = 25°C, VDD = 3.0 V if nothing else stated  
Parameter  
Min.  
Typ.  
Max.  
Unit Condition / Note  
Transmit Section  
Transmit data rate  
0.6  
0
76.8  
65  
kBaud NRZ or Manchester encoding.  
76.8 kBaud equals 76.8 kbit/s  
using NRZ coding. See page 16.  
Binary FSK frequency separation  
kHz  
The frequency separation is  
programmable in 250 Hz steps.  
65 kHz is the maximum  
guaranteed separation at 1 MHz  
reference frequency. Larger  
separations can be achieved at  
higher reference frequencies.  
SWRS048A  
Page 4 of 55