Analysis Mode
3
Analysis Mode
In Analysis mode, the ADS1x31REF analyzes code output from the installed ADS device and displays it in
different ways.
summarizes the numerous display modes available, together with example
displays.
NOTE:
The values shown in
are consistent for a 24-bit device, such as the ADS1231.
However, the ADS1131 is an 18-bit device, so the actual number of codes will be fewer than
the examples shown here.
Table 3. Modes and Example Displays
Hex Code
Raw
RMS
Peak-to-Peak
Averaged
1992E9H
n/a
n/a
n/a
Dec Code
+1676001
+5.789
+31.256
+1676001
Voltage
+499.488M
+17.495N
+90.293N
+499.488M
ENOB
n/a
+23.18BIT
+21.92BIT
n/a
The ADS1x31REF operates in Analysis mode when the mode switch is set to the
ANALYSIS
position.
The default Analysis mode is RAW HEX.
To change measurement types, hold down
DISP
and press
MODE.
This function cycles through the four
available measurement types. When
DISP
is released, the newly selected measurement is made. To
change units, press
UNIT.
This option cycles through the available units for the active measurement type.
This procedure can also be done while
DISP
is depressed; in that case, the new unit is shown by name
on the display. The measurement modes are described in detail in
The ADS1131 or ADS1231 itself can be configured directly from this mode, as described in
3.1
Switch Functions
NEW BLOCK:
Pressing this switch resets the collection process for the RMS, peak-to-peak, and
averaged measurements.
UNIT:
Cycles between available units. Not all units are available in all modes.
DISP:
When this switch is pressed, the display shows the current measurement mode and unit. While
DISP
is still pressed, pressing
NEW BLOCK / MODE
cycles through the available measurement modes.
CHIP:
Holding this switch down allows the settings of the installed ADS device to be changed, using the
PARM (NEW BLOCK)
and
VAL (UNIT)
buttons.
Pressing
PARM
while
CHIP
is pressed down cycles through the available parameters of gain and data
rate.
The gain setting is displayed as
GAIN=
followed by the gain setting. The gain setting is for display only,
because the gain is fixed at 64 for the ADS1131 and 128 for the ADS1231.
Data rate is shown on the display as
SPD=FAST
or
SPD=SLOW
. See
in the
section
for further information.
If any of these parameters are changed during a multisample measurement, the measurement is
restarted.
SBAU175A
July 2010
Revised August 2011
ADS1131REF and ADS1231REF
11
Copyright
©
2010–2011, Texas Instruments Incorporated