欢迎访问ic37.com |
会员登录 免费注册
发布采购

ADS1201U 参数 Datasheet PDF下载

ADS1201U图片预览
型号: ADS1201U
PDF下载: 下载PDF文件 查看货源
内容描述: 高动态范围Δ-Σ调制 [High Dynamic Range DELTA-SIGMA MODULATOR]
分类和应用: 转换器光电二极管
文件页数/大小: 17 页 / 332 K
品牌: TI [ TEXAS INSTRUMENTS ]
 浏览型号ADS1201U的Datasheet PDF文件第5页浏览型号ADS1201U的Datasheet PDF文件第6页浏览型号ADS1201U的Datasheet PDF文件第7页浏览型号ADS1201U的Datasheet PDF文件第8页浏览型号ADS1201U的Datasheet PDF文件第10页浏览型号ADS1201U的Datasheet PDF文件第11页浏览型号ADS1201U的Datasheet PDF文件第12页浏览型号ADS1201U的Datasheet PDF文件第13页  
BIAS
EN
LOW
HIGH
V
BIAS
High Impedance
1.33V • V
REF
TABLE II. Bias Enable.
When enabled, the V
BIAS
circuitry consumes approximately
1mA with no external load. The maximum current into or
out of V
BIAS
should not exceed 10mA.
On power-up, external signals may be present before V
BIAS
is enabled. This can create a situation in which a negative
voltage is applied to the analog inputs, reverse biasing the
negative input protection diode of the ADS1201. This situ-
ation should not be a problem as long as the resistors R
1
and
R
2
limit the current being sourced by each analog input to be
under 10mA. A potential of 0V at the analog input pin (A
IN
P
or A
IN
N) should be used in the calculation.
DIGITAL OUTPUT
The timing diagram for the ADS1201 data retrieval is shown
in Figure 7. MCLK initiates the modulator process for the
ADS1201 and is used as a system clock by the ADS1201, as
well as a framing clock for data out. The modulator output
data, which is a serial stream, is available on the MOUT pin.
Typically, MOUT is read on the falling edge of MCLK.
Under any situation with MCLK, the duty cycle must be
kept constant for reliable, repeatable results.
An input differential signal of 0V will ideally produce a
stream of ones and zeros that are HIGH 50% of the time and
LOW 50% of the time. A differential input of 5V will
produce a stream of ones and zeros that are HIGH 90% of
the time. A differential input of –5V will produce a stream
of ones and zeros that are HIGH 10% of the time. The input
voltage versus the output modulator signal is shown in
Figure 8.
OFFSET and GAIN CALIBRATION
The ADS1201 offers a self-calibration function that is imple-
mented with the GAIN/OFFSET and CAL
EN
pins. Both
conditions provide an output stream of data, similar to
normal operation where the converter is configured to sample
an input signal at A
IN
.
The offset and gain errors of the ADS1201 are calibrated
independently. For best operation, the offset should be
calibrated first, followed by the gain. The calibration imple-
mentation timing diagram is shown in Figure 9. The calibra-
tion mode pins control the calibration functions of the
ADS1201.
Calibration should be performed once and then normal
operation can be resumed. Calibration of offset and gain is
recommended immediately after power-on and whenever
there is a “significant” change in the operating environment.
Significant changes in the operating environment include a
change of the MCLK frequency, MCLK duty cycle, power
Modulator Output
+FS (Analog Input)
–FS (Analog Input)
Analog Input
FIGURE 8. Analog Input versus Modulator Output of the ADS1201.
t
9
CAL
t
8
SYMBOL
t8
t
8
t
9
t
11
t9
t10
t11
DESCRIPTION
CAL and GAIN/OFFSET Rise Time
CAL and GAIN/OFFSET Fall Time
GAIN/OFFSET to CAL Setup Time
GAIN/OFFSET to CAL Hold Time
0
2.5 T
MCLK(1)
MIN
TYP
10
10
MAX
UNITS
ns
ns
ns
ns
GAIN/OFFSET
t
10
NOTE: (1) T
MCLK
is the clock period of MCLK.
FIGURE 9. Timing Diagram for the Calibration Feature of the ADS1201.
®
9
ADS1201