54AC11027, 74AC11027
TRIPLE 3-INPUT POSITIVE-NOR GATES
SCAS019A – JULY 1987 – REVISED APRIL 1993
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
T
A
= 25°C
54AC11027
74AC11027
PARAMETER
TEST CONDITIONS
V
UNIT
CC
MIN
2.9
TYP
MAX
MIN
2.9
4.4
5.4
2.4
3.7
4.7
3.85
MAX
MIN
2.9
MAX
3 V
4.5 V
5.5 V
3 V
I
= – 50 µA
4.4
4.4
OH
5.4
5.4
I
I
= – 4 mA
2.58
3.94
4.94
2.48
3.8
OH
V
OH
V
4.5 V
5.5 V
5.5 V
5.5 V
3 V
= – 24 mA
= – 50 mA
OH
4.8
†
I
I
OH
†
= –75 mA
3.85
OH
0.1
0.1
0.1
0.1
0.1
0.1
I
= 50 µA
4.5 V
5.5 V
3 V
OL
0.1
0.1
0.1
I
I
= 12 mA
= 24 mA
0.36
0.36
0.36
0.5
0.44
0.44
0.44
OL
V
OL
V
4.5 V
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
5 V
0.5
OL
0.5
†
†
I
I
= 50 mA
1.65
OL
= 75 mA
1.65
±1
OL
I
I
V = V
or GND
or GND,
or GND
±0.1
±1
µA
µA
pF
I
I
CC
CC
CC
V = V
I = 0
O
4
80
40
CC
I
C
V = V
3.5
i
I
†
Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
switching characteristics over recommended operating free-air temperature range,
= 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
V
CC
T
A
= 25°C
TYP
6.3
54AC11027
74AC11027
FROM
(INPUT)
TO
(OUTPUT)
PARAMETER
UNIT
MIN
1.5
MAX
9.8
MIN
1.5
MAX
MIN
1.5
MAX
10.9
12
t
t
11.7
12.9
PLH
Any
Y
ns
1.5
7.6
10.9
1.5
1.5
PHL
switching characteristics over recommended operating free-air temperature range,
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
V
CC
T
A
= 25°C
TYP
4.3
54AC11027
74AC11027
FROM
(INPUT)
TO
(OUTPUT)
PARAMETER
UNIT
MIN
1.5
MAX
6.8
MIN
1.5
MAX
MIN
1.5
MAX
7.7
t
t
8.1
8.9
PLH
Any
Y
ns
1.5
4.5
7.5
1.5
1.5
8.1
PHL
operating characteristics, V
= 5 V, T = 25°C
A
CC
PARAMETER
Power dissipation capacitance per gate
TEST CONDITIONS
CL = 50 pF, f = MHz
TYP
24
UNIT
C
pF
pd
2–3