THC63LVD824A _Rev1.20_E
Note
1)Power On Sequence
Power on LVDS-Tx after THC63LVD824A. If it is not avoidable, please contact to
mspsupport@thine.co.jp (for FAE mailing list)
2)Cable Connection and Disconnection
Don't connect and disconnect the LVDS cable , when the power is supplied to the system.
3)GND Connection
Connect the each GND of the PCB which LVDS-Tx and THC63LVD824A on it. It is better for EMI reduction to place
GND cable as close to LVDS cable as possible.
4)Multi Drop Connection
Multi drop connection is not recommended.
TCLK+
LVDS-Tx
THC63LVD824A
THC63LVD824A
TCLK-
5)Asynchronous use
Asynchronous use such as following systems are not recommended. If it is not avoidable, please contact to
mspsupport@thine.co.jp (for FAE mailing list)
CLKOUT
DATA
TCLK+
TCLK-
CLKOUT
DATA
LVDS-Tx
LVDS-Tx
THC63LVD824A
THC63LVD824A
IC
IC
CLKOUT
DATA
TCLK+
TCLK-
DATA
TCLK+
TCLK-
CLKOUT
DATA
THC63LVD824A
THC63LVD824A
IC
IC
TCLK+
TCLK-
DATA
Copyright©2014 THine Electronics, Inc.
12/14
THine Electronics, Inc.