DS_6613_018
78M6613 Data Sheet
>1µs
>1µs
Max
Typ
Min
0.0V
Time
V3P3
RESET
Figure 11: 78M6613 External Reset Behavior
The RESET signal can be generated in a number of different ways. For example, a voltage supervisory
device such as Maxim’s MAX810S can be us ed to implement the reset/supply voltage supervisory
function as shown in Figure 12.
V3P3
Vcc
MAX810S
RST
GND
RESET
78M6613
GND
Figure 12: MAX810S Connections to the 78M6613
Rev. 1.1
17