DS_6612_001  
78M6612 Data Sheet  
The CE is initialized by the MPU using CECONFIG (CESTATE.). This register contains in packed form  
SAG_CNT, FREQSEL, EXT_PULSE, I1_SHUNT, I2_SHUNT, PULSE_SLOW, and PULSE_FAST.  
CE  
Address  
Name  
Default  
Description  
0x0E  
CECONFIG  
0x5001  
See description of CECONFIG below.  
The significance of the bits in CECONFIG is shown in the table below.  
The CE controls the pulse rate based on W1SUM_X + W2SUM_X (and VAR1SUM_X + VAR2SUM_X).  
Note: The 78M6612 Demo Code creep function halts pulse generation.  
CECONFIG  
Name  
Default Description  
[bit]  
Number of consecutive voltage samples below SAG_THR  
before a sag alarm is declared. The maximum value is  
255. SAG_THR is at address 0x14.  
80  
(0x50)  
SAG_CNT  
[15:8]  
[7]  
[6]  
[5]  
0
0
0
Unused  
Unused  
Unused  
Selects outlet to be used for pulse generation.  
PULSESEL  
[4]  
0
0 = A  
1 = B  
Current sensor selection.  
SENSORSEL  
[3:2]  
11  
00 = CT  
11 = Shunt  
When PULSE_SLOW = 1, the pulse generator input is  
reduced by a factor of 64. When PULSE_FAST = 1, the  
pulse generator input is increased 16x. These two  
parameters control the pulse gain factor X (see table  
below). Allowed values are 1 or 0. Default is 01 (X = 6/64).  
PULSE_FAST  
PULSE_SLOW  
[1]  
[0]  
0
0
X
PULSE_FAST  
PULSE_SLOW  
1.5 * 22 = 6  
1.5 * 2-4 = 0.09375  
1.5 * 26 = 96  
1.5  
0
0
1
1
0
1
0
1
4.4.7 CE Transfer Variables  
When the MPU receives the XFER_BUSY interrupt, it knows that fresh data is available in the transfer  
variables. The transfer variables can be categorized as:  
1. Fundamental energy measurement variables  
2. Instantaneous (RMS) values  
3. Other measurement parameters  
4. Pulse generation variables  
5. Current shunt variables  
6. Calibration parameters  
Rev. 1.2  
85